Chapter 6: Advanced Chassis Setup
6-3
6-3 System
Fans
Five 4-cm heavy duty counter-rotating fans provide the cooling for the 6016T-
6RFT+/6016T-6RF+. Each fan unit is actually made up of two fans joined back-
to-back, which rotate in opposite directions. This counter-rotating action generates
exceptional airfl ow and works to dampen vibration levels.
It is very important that the chassis top cover is properly installed and making a
good seal in order for the cooling air to circulate properly through the chassis and
cool the components. See Figure 6-2.
System Fan Failure
Fan speed is controlled by system temperature via a BIOS setting. If a fan fails,
the remaining fan will ramp up to full speed and the overheat/fan fail LED on the
control panel will turn on. Replace any failed fan at your earliest convenience with
the same type and model (the system can continue to run with a failed fan).
Remove the top chassis cover while the system is still running to determine which of
the fans has failed. Then power down the system before replacing a fan. Removing
the power cord(s) is also recommended as a safety precaution.
Replacing System Fans
After determining which fan has failed, turn off the power to the system.
1.
Unplug the fan cable from the serverboard and remove the failed fan from the
2.
chassis.
Replace the failed fan with an identical 4-cm, 12 volt fan (available from
3.
Supermicro: p/n FAN-0086L4).
Push the new fan into the vacant space in the housing while making sure the
4.
arrows on the top of the fan (indicating air direction) point in the same direc-
tion as the arrows on the other fans.
Reposition the fan housing back over the two mounting posts in the chassis,
5.
then reconnect the fan wires to the same chassis fan headers you removed
them from.
Power up the system and check that the fan is working properly and that the
6.
LED on the control panel has turned off.
Finish by replacing the chassis cover.
7.
Summary of Contents for 6016T-6RFT
Page 1: ...SUPERSERVER 6016T 6RFT SUPERSERVER 6016T 6RF SUPER USER S MANUAL 1 0 ...
Page 5: ...v Preface Notes ...
Page 21: ...Chapter 2 Server Installation 2 7 Figure 2 3 Installing the Server into a Rack ...
Page 23: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the System ...
Page 28: ...3 4 SUPERSERVER 6016T 6RFT 6016T 6RF User s Manual Notes ...
Page 71: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 5 Removing Replacing the Power Supply 1 2 ...
Page 72: ...6 10 SUPERSERVER 6016T 6RFT 6016T 6RF User s Manual Notes ...
Page 102: ...7 30 SUPERSERVER 6016T 6RFT 6016T 6RF User s Manual Notes ...
Page 104: ...A 2 SUPERSERVER 6016T 6RFT 6016T 6RF User s Manual Notes ...