12
Chapter 1: Introduction
Control Panel Features
Feature
Description
Power button
The main power switch applies or removes primary power from the power supply to the
associated node but maintains standby power. The power button has a built-in LED which
turns green when the power is on.
NIC LED
Indicates network activity on LANs when flashing.
Information LED Alerts operator to several states, as noted in the table below
UID button/LED
BMC reset
The unit identification (UID) button turns on or off the blue light function of the Information
LED and a blue LED on the rear of the chassis. This can be used to locate the node.
The BMC can be reset using the UID switch. See
Control Panel
Figure 1-2. Control Panel
Power Button
Information LED
UID Button/LED
BMC Reset
NIC LED
Information LED
Color, Status
Description
Red, solid
An overheat condition has occurred.
Red, blinking at 1Hz
Fan failure, check for an inoperative fan.
Red, blinking at 0.25Hz
Power failure, check for a non-operational power
supply.
Red, solid, with Power LED blinking
green
Fault detected
Blue and red, blinking at 10 Hz
Recovery mode
Blue, solid
UID has been activated locally to locate the
server in a rack environment.
Blue, blinking at 1Hz
UID has been activated using the BMC to locate
the server in a rack environment.
Blue, blinking at 2Hz
BMC is resetting
Blue, blinking at 4Hz
BMC is setting factory defaults
Blue, blinking at 10Hz with Power LED
blinking green
BMC/BIOS firmware is updating