Figure 6-9. Installing the Backplane
Installing the Backplane
Installing the Backplane into the Chassis (Figure 6-9)
1. Ensure that all of the hard drive trays have been removed from the bays in the
front of the chassis and that the spring bar has been loosened as directed in
the previous section.
2. Secure the side mounting bracket to the backplane with the two screws provided.
3. Slide the backplane into the chassis at a slight angle, pushing it up against the
side of the chassis.
4. Ease the backplane forward, against the front of the chassis. This will aid in the
alignment of the mounting holes.
5. Align the mounting holes in the backplane with the holes in the chassis. Replace
the four screws at the top of the backplane and the screw on the side of the
chassis.
6.
Adjust the spring bar, then tighten the spring bar screws in the floor of the
chassis.
7. Replace the side screw in the side of the chassis
8. Reconnect all cables and return the hard drive trays to their bays in the front
of the chassis.
Summary of Contents for SUPERSERVER 6028R-E1CR16T
Page 1: ...SUPER User s Manual Revision 1 0 SUPERSERVER 6028TP DNCR 6028TP DCNTR 6028TP DCNFR...
Page 5: ...v SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual Notes...
Page 10: ...x Notes SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual...
Page 18: ...1 8 SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual Notes...
Page 81: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...
Page 95: ...Chapter 6 Advanced Chassis Setup 6 21 Release Tab Figure 6 19 Changing the Power Supply...
Page 96: ...6 22 SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual Notes...
Page 138: ...A 2 SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual Notes...