5-4
SUPERSERVER 6028TP-DNCR/DNCTR/DNCFR User's Manual
5-4 Processor and Heatsink Installation
Notes:
•
Always remove the power cord before adding, removing or changing a CPU.
•
When receiving a serverboard without a processor pre-installed, make sure that
the plastic CPU socket cap is in place and none of the socket pins are bent;
otherwise, contact your retailer immediately.
•
If you buy a CPU separately, use only an Intel-certified, multi-directional heatsink.
•
Avoid placing direct pressure to the top of the processor package.
•
Install the processor into the CPU socket before installing the heatsink.
•
Refer to the Supermicro web site for updates on CPU support.
Release the lever labeled "Open 1st"
Installing a CPU
1. There are two levers on the LGA
2011 socket. First press and release
the load lever labeled "Open 1st".
OPEN 1s
t
OPEN 1s
t
Release the lever labeled "Close 1st"
2. Press the second load lever labeled
"Close 1st" to release the load plate
from its locked position.
Summary of Contents for SUPERSERVER 6028R-E1CR16T
Page 1: ...SUPER User s Manual Revision 1 0 SUPERSERVER 6028TP DNCR 6028TP DCNTR 6028TP DCNFR...
Page 5: ...v SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual Notes...
Page 10: ...x Notes SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual...
Page 18: ...1 8 SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual Notes...
Page 81: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...
Page 95: ...Chapter 6 Advanced Chassis Setup 6 21 Release Tab Figure 6 19 Changing the Power Supply...
Page 96: ...6 22 SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual Notes...
Page 138: ...A 2 SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual Notes...