7-18
SUPERSERVER 6028TP-DNCR/DNCTR/DNCFR USER'S MANUAL
SATA Configuration
When this submenu is selected, AMI BIOS automatically detects the presence of
the SATA devices that are supported by the Intel PCH chip and displays the fol-
lowing items:
SATA Controller
This item enables or disables the onboard SATA controller supported by the Intel
PCH chip. The options are
Enabled
and Disabled.
Configure SATA as
Select IDE to configure a SATA drive specified by the user as an IDE drive. Select
AHCI to configure a SATA drive specified by the user as an AHCI drive. Select
RAID to configure a SATA drive specified by the user as a RAID drive. The options
are IDE,
AHCI
, and RAID.
*If the item above "Configure SATA as" is set to AHCI, the following items will display
:
Support Aggressive Link Power Management
When this item is set to Enabled, the SATA AHCI controller manages the power
usage of the SATA link. The controller will put the link to a low power state when
the I/O is inactive for an extended period of time, and the power state will return
to normal when the I/O becomes active. The options are
Enabled
and Disabled.
SATA Port 0~ Port 5
This item displays the information detected on the installed SATA drive on the
particular SATA port.
•
Model number of drive and capacity
•
Software Preserve Support
Port 0~ Port 5
Select Enabled to enable a SATA port specified by the user. The options are
Disabled and Enabled.
Port 0 ~ Port 5 Hot Plug
Select Enabled to enable hot-plugging support for a port specified by the user,
which will allow the user to replace a SATA disk drive installed on this port without
shutting down the system. The options are
Enabled
and Disabled.
Port 0 ~ Port 5 Spin Up Device
On an edge detect from 0 to 1, set this item to allow the PCH to initialize the
device. The options are Enabled and
Disabled
.
Summary of Contents for SUPERSERVER 6028R-E1CR16T
Page 1: ...SUPER User s Manual Revision 1 0 SUPERSERVER 6028TP DNCR 6028TP DCNTR 6028TP DCNFR...
Page 5: ...v SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual Notes...
Page 10: ...x Notes SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual...
Page 18: ...1 8 SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual Notes...
Page 81: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...
Page 95: ...Chapter 6 Advanced Chassis Setup 6 21 Release Tab Figure 6 19 Changing the Power Supply...
Page 96: ...6 22 SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual Notes...
Page 138: ...A 2 SUPERSERVER 6028TP DNCR DNCTR DNCFR User s Manual Notes...