Checking the Components and Setup
1. You may have one or two processors already installed into the serverboard.
Each processor needs its own heat sink. See Chapter 5 for instructions on
processor and heat sink installation.
2. Your SuperServer 6018TR-T/TF server system may have come with system
memory already installed. Make sure all DIMMs are fully seated in their slots.
For details on adding system memory, refer to Chapter 5.
3. If desired, you can install add-on cards to the system. See Chapter 5 for
details on installing PCI add-on cards.
4. Make sure all power and data cables are properly connected and not blocking
the chassis airfl ow. Also make sure that no cables are positioned in front of
the fans. See Chapter 5 for details on cable connections.
2-7 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the SATA drives
have been properly installed and all connections have been made.
Checking the Drives
1. All drives are accessable from the front of the server. A hard drive can be
installed and removed from the front of the chassis without removing the top
chassis cover.
2. Depending upon your system's confi guration, your system may have one or
more drives already installed. If you need to install hard drives, please refer to
Chapter 6.
Checking the Airfl ow
1. Airfl ow is provided by six hot-swappable 4-cm chassis cooling fans in two
housings. The system component layout was carefully designed to direct
suffi cient cooling airfl ow to the components that generate the most heat.
2. Note that all power and data cables have been routed in such a way that they
do not block the airfl ow generated by the fans.
Providing Power
1. Plug the power cord(s) from the power supply unit(s) into a high-quality
power strip that offers protection from electrical noise and power surges. It is
recommended that you use an uninterruptible power supply (UPS).
2. Depress the power on button on the front of the chassis.
Caution: Except for short periods of time, do NOT operate the server without
the cover in place. The chassis cover must be in place to allow proper airfl ow
and prevent overheating.
Summary of Contents for SUPERSERVER 6018TR-T
Page 1: ...SUPERSERVER 6018TR T 6018TR TF USER S MANUAL Revision 1 0...
Page 5: ...v SUPERSERVER 6018TR T TF User s Manual Notes...
Page 10: ...x Notes SUPERSERVER 6018TR T TF User s Manual...
Page 84: ...5 32 SUPERSERVER 6018TR T TF User s Manual Notes...
Page 98: ...6 14 SUPERSERVER 6018TR T TF User s Manual Release Tab Figure 6 14 Changing the Power Supply...
Page 140: ...A 2 SUPERSERVER 6018TR T TF User s Manual Notes...