B-2
SUPERSERVER 8048B-TR4FT USER'S MANUAL
Chassis
SC848XTS-R3240BP (4U rackmount)
Dimensions: (WxHxD) 17.2 x 1.7 x 32.1 in. (437 x 43 x 815 mm)
Weight
Gross (Bare Bone): 150 lbs. (68 kg.)
System Cooling
The system has Four 9-cm and three 8-cm system fans and three 8-cm rear
exhaust fans (fan speed controlled by IPMI)
System Input Requirements
AC Input Voltage: 100 - 240V AC auto-range
Rated Input Current: 11.5 - 5.5A max
Rated Input Frequency: 50 to 60 Hz
Power Supply (2+2 redundant)
Rated Output Power: 1620W (Part# PWS-1K62P-1R)
Rated Output Voltages: +12V (84A at 100-120VAC, 100A at 120-140VAC, 135A
at 180-264VAC), +5Vsb (4A)
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)