2-8
SUPERSERVER 8048B-TR4FT USER'S MANUAL
Figure 2-4. Installing the Chassis into a Rack
Installing the Chassis into a Rack
Installing the Chassis into a Rack:
1. Confi rm that chassis includes the inner rails (A) Also, confi rm that the outer
rails (B) are installed on the rack.
2. Line chassis rails (A) with the front of the rack rails (B).
3. Slide the chassis rails into the rack rails, keeping the pressure even on both
sides (you may have to depress the locking tabs when inserting). When the
server has been pushed completely into the rack, you should hear the locking
tabs "click" into the locked position.
4. Tighten up all the screws on the front side and rear side of both outer rails.
5. (Optional) Insert and tightening the thumbscrews that hold the front of the
server to the rack.
1
A
1
B
Note:
fi gures are for illustrative purposes only. Always install servers into racks
from the bottom up.