Chapter 5: Advanced Serverboard Setup
5-13
Overheat/Fan Fail LED (OH)
Connect an LED to the OH connection
on pins 7 and 8 of JF1 to provide ad-
vanced warning of chassis overheat-
ing. Refer to the table on the right for
pin defi nitions.
HDD LED
The HDD LED connection is located
on pins 13 and 14 of JF1. This LED
is used to display all IDE and SAS
activity. See the table on the right for
pin defi nitions.
OH/Fan Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition
7
Vcc
8
Ground
NIC2 LED
Pin Defi nitions (JF1)
Pin# Defi nition
9
Vcc
10
Ground
HDD LED
Pin Defi nitions (JF1)
Pin# Defi nition
13
Vcc
14
HD Active
NIC2 (JLAN2) LED
The LED connections for JLAN2 are
on pins 9 and 10 of JF1. Attach an
LED cable to display network activ-
ity. See the table on the right for pin
defi nitions.
NIC1 LED
Pin Defi nitions (JF1)
Pin# Defi nition
11
Vcc
12
Ground
NIC1 (JLAN1) LED
The LED connections for JLAN1 are
on pins 11 and 12 of JF1. Attach an
LED cable to display network activ-
ity. See the table on the right for pin
defi nitions.
OH/Fan Fail Indicator
Status
State Defi nition
Off
Normal
On
Overheat
Flash-
ing
Fan Fail
Summary of Contents for 8025C-3R
Page 1: ...SUPER SUPERSERVER 8025C 3R USER S MANUAL Revision 1 0a...
Page 5: ...v Preface Notes...
Page 22: ...2 8 SUPERSERVER 8025C 3R User s Manual Notes...
Page 26: ...3 4 SUPERSERVER 8025C 3R User s Manual Notes...
Page 63: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 6 Removing a Power Supply Module...
Page 64: ...6 10 SUPERSERVER 8025C 3R User s Manual Notes...
Page 90: ...7 26 SUPERSERVER 8025C 3R User s Manual Notes...
Page 96: ...A 6 SUPERSERVER 8025C 3R User s Manual Notes...
Page 102: ...B 6 SUPERSERVER 8025C 3R User s Manual Notes...