7-20
SUPERSTORESYSTEM 6048R-DE2CR24L User's Manual
Hot Plug
Select Enabled to enable hot-plugging support for a port specifi ed by the user,
which will allow the user to replace a SATA disk drive installed on this port without
shutting down the system. The options are
Enabled
and Disabled.
Spin Up Device
On an edge detect from 0 to 1, set this item to allow the PCH to start a
COMRESET initialization to the device. The options are Enabled and
Disabled
.
sSATA Device Type
Use this item to specify if the sSATA port specifi ed by the user should be
connected to a Solid State drive or a Hard Disk Drive. The options are
Hard
Disk Drive
and Solid State Drive.
Server ME (Management Engine) Confi guration
This feature displays the following system ME confi guration settings.
•
General ME Confi guration
•
Operational Firmware Version
•
Recovery Firmware Version
•
ME Firmware Features
•
ME Firmware Status #1
•
ME Firmware Status #2
•
Current State
•
Error Code