- 12 -
RDO1 C
GENERAL FITTING REQUIREMENTS
9.
TESTING THE CLOSE CYCLE FORCE
With the door in the fully open position, place a length of timber measuring 100mm x 50mm on the floor
directly under the middle of the door.
Fig 14
Fig 14
Close the door by pressing the red button. The door should strike the timber and start to re-open.
If the door does not re-open or requires excessive force to re-open, then the Close “SOF” will need to be
re-adjusted.
Try turning the Close “SOF” adjusting screw 5 to 10 degrees in an anti-clockwise direction and then repeat
steps 8.2 and 8.3 until such time as the door will reverse when it hits the timber.
10. TESTING THE OPEN CYCLE FORCE
10.1
With the door in the fully closed position – press the red button to open the door.
10.2
As the door is opening push down firmly on the bottom rail of the door (from the inside)
10.3
The door should stop without having to exert excessive force.
10.4
If excessive force is required to stop the door then the Open “SOF” will need to be re-adjusted.
10.5
Try turning the Close “SOF” adjusting screw 5 to 10 degrees in an anti-clockwise direction and then repeat
steps 8.5 and 10.2 until such time as the door will stop without excessive force.
IMPORTANT NOTE: Upon hitting an obstruction – If the door STOPS on the DOWN CYCLE and
REVERSES on the UP CYCLE then the motor wires are incorrectly connected and MUST BE reversed to
enable safe and correct operation of the safety reversing system
11.
LOCKING AND THE RELEASING DRIVE MECHANISM
11.1 Pull on the Red Release cord, or turn the release handle manually, to alternatively lock/release the drive
mechanism
12. FITTING OF PHOTO ELECTRIC (PE) SAFETY BEAMS (OPTIONAL)
12.1
Mount the PE beam brackets in accordance with.
Summary of Contents for RDO1 C
Page 1: ...801 001 01 C...