GENERAL FITTING REQUIREMENTS
2.3 Open the door slightly so as to have access to the marked positions. Secure the curtain to the drum wheel
using self drilling screws or pop rivets. The fixing point should be at least 90 degrees apart.
3.
SETTING THE LIMIT SWITCHES
3.1 With the Drive Unit in release mode move the door up by hand to the desired fully open position.
3.2 Remove the limit cover
Fig 2
and slightly loosen the 3 cam locking screws (to the extent that you can rotate
the cam by hand with a firm push). Rotate the Open Limit Cam by hand, in the direction of the Open Limit
Switch, until you hear the Switch “click”
Fig 2
.
Once the Open Limit Switch “clicks” continue to rotate
the cam a further 5 degrees or so.
3.3 To check the Open Limit Switch adjustment - Move the door down by hand and then slowly back up again.
The limit switch should “click” before the door stops make contact with the rail stops. If not then adjust
the Open Limit Cam accordingly.
3.4 To set the Close Limit Switch - Move the door down by hand to the desired fully closed position.
3.5 Rotate the Close Limit Cam by hand, in the direction of the Close Limit Switch, until you hear the Switch
“click”. Once the Open Limit Switch “clicks” continue to rotate the Cam a further 5 degrees or so.
3.6 To check the Down Limit Switch adjustment, raise the door by hand and then slowly lower again. The
Down Limit Switch should “click” just before the door touches the ground. If not then adjust the Close
Limit Cam accordingly.
3.5 Slightly re-tighten the 3 Cam Locking Screws
Fig 2
3.6 Pull the Red Lock/Release Chord to engage the drive and the Opener is ready to be used in automatic
mode once the Control Box
Fig 3
has been installed
4.
MOUNTING THE CONTROL BOX
4.1
Establish a location, at approximately chest height, on the same wall face as that of the Door Mounting
Bracket which secures the Drive Unit. Make sure that the Control Cable running from the Drive Unit is
long enough to reach the bottom of the Control Box for the location you have selected.
4.2
Drill a 6mm hole, to an appropriate depth, in the wall and insert a green wall plug and screw provided
4.3
Remove the top cover of the Control Box by bending the flexible tab along the bottom edge taking care to
unplug the external push button wire from it’s respective terminal.
4.4
Locate the recessed mounting slot on the center back of the Control Box base plate and “hook” the base
plate onto the screw (Point 4.2)
4.5
Using a marking pen or nail, place 2 marks on the wall at the location of the remaining 2 mounting screw
holes
4.6
Remove the Base Plate from the wall and drill to an appropriate depth at the 2 marks on the wall.
4.7
Insert the green wall plugs provided and re-hang the Base Plate onto the wall.
4.8
Insert and tighten the 2 remaining mounting screws.
4.9
Refit the Control Box Cover onto the Base Plate remembering to reconnect the external push button wire
to the appropriate terminal
Fig 1
4.10
Plug the Control Cable into the bottom of the Control Box.
4.11
Fix the Control Cable to the wall using the Cable Clips provided.
4.12
Plug the Power Cable into a power socket.