- 13 -
RDO1 C
GENERAL FITTING REQUIREMENTS
12.2
Fix the PE beams to the mounting brackets with the screws provided
12.3
Strip back a section of wire and attach it to the 2 terminals on each of the PE beams
12.4
Run the wire back to the Control Box and connect to terminals
Fig 1
12.5
Align the photo beams so that the pilot light, at the top edge of each photo beam, is glowing.
12.6
To enable the photo beams switch dip switch Number 1
to the “ON” position.
Fig 1
12.7
To test the correct function of the PE beam – with the door in the fully open position – press the red button
to commence a closing cycle. As the door is closing pass your hand through the line of the PE beam. The
door should stop and then re-open.
12.8
If the door does not stop and/or re-open, check the wiring connections and the PE beam alignment. (Refer
points 11.3, 11.5 and 11.6)
13.
AUTO CLOSE FUNCTION
To enable the auto close function, switch dip switch “Number 2”
to the “ON” position.
IMPORTANT NOTE: The fitment of PE beams is mandatory once the auto close function has been
enabled. The Auto Close will not function unless the PE beams have been correctly fitted and adjusted
14. AUTO CLOSE DELAY TIME
Select the delay time to auto close according to the following schedule
Dip 3 Dip4 Time Delay
OFF OFF
15 sec
ON OFF
30 sec
OFF ON
45 sec
ON ON
60 sec
TECHNICAL SPECIFICATIONS
CONFIGURATION:
Separate Control Box & Drive Unit
INPUT VOLTAGE:
230V or 115V 50~60 H (Selectable)
SECONDARY VOLTAGE:
24V AC 120 VA
CONTROLER VOLTAGE:
24V DC
OPENER LIFTING FORCE:
300N
OPENER OPENING/CLOSING LIMITS TRAVEL:
4.5 Turns of Door Drum Wheel
RECEIVER TYPE:
UHF 433.92 MHz Hopping Code
RECEIVER CODE STORAGE CAPACITY:
6 x 4 Button Transmitter Codes
TRANSMITTER FREQUENCY:
433 MHz
No. of CODE COMBINATIONS:
Over 4.9 Billion
TRANSMITTER BATTERY VOLTAGE:
12 Volt
MOTOR TYPE:
24 Volt DC Permanent Magnet
GLOBE:
15W 24 V DC Edison screw Type
SAFETY REVERSING SYSTEM:
Pot Adjustable Current Sensing
Summary of Contents for RDO1 C
Page 1: ...801 001 01 C...