8

Hemmed 

End

8" Stainless 

Inner Pipe

12 

3

/

8

Galvanized 

Outer Pipe

 WARNING: The opening in collar around chimney 

at top of fireplace must not be obstructed. Never use 

blown insulation to fill chimney enclosure

.

VENTING INSTALLATION 

Continued

ASSEMBLY AND INSTALLATION OF DOUBLE WALL CHIMNEY 

SYSTEM

Each double wall chimney section consists of a galvanized outer 

pipe, a stainless steel inner flue pipe and a wire spacer. Pipe sections 

must be assembled independently as chimney is installed. When 

connecting chimney directly to fireplace, inner flue pipe section 

must be installed first with lanced side up. Outer pipe section can 

then be installed over flue pipe section with hemmed end up. Press 

down on each pipe section until lances securely engage hem on 

fireplace starter. Wire will assure proper spacing between inner 

and outer pipe sections.

Note:

 For Canada, use chimney parts designated HT.

 Opening in collar around chimney at top of 

fireplace must not be obstructed. Never use blown 

insulation to fill chimney enclosure.

Continue to assemble chimney sections as outlined, making sure 

that both inner and outer pipe sections are locked together. When 

installing double wall snap-lock chimney together, it is important to 

assure joint between chimney sections is locked. Check by pulling 

chimney upward after locking. Chimney will not come apart if properly 

locked. It is not necessary to add screws to keep chimney together 

(exception - see Figure 11, page 9).
The height of a vertical chimney pipe supported ONLY by the fireplace, 

must not exceed 20 feet. Chimney heights above 20 feet must be 

supported.

USING ELBOW OFFSETS (30E-8DM)

1.  To achieve desired offset, you may install combinations of 12", 

18", 24", 36" and 48" length of double wall pipe (see offset chart, 

page 9, and Figure 9, page 8).

  Note: For systems with 2 elbow sets, minimum height is 22 feet. 

Maximum height for any system is 50 feet.

2.  Chimney weight above offset rests on return elbow. Straps must 

be securely nailed to rafters or joists (see Figure 10, details A and 

B, page 8).

3.  Maximum length of pipe between supports (return elbow or 12S-

8DM) is 6' of angle run. Maximum of two 6' angle run sections 

per chimney system (see Figure 9, page 9).

4.  All pipe connections between offset and return must be secured 

with two screws on outer pipe only (see Figure 11, page 10). Do 

not penetrate inner stainless.

Figure 8 - Lineal Gain

LINEAL GAIN

CAT. NO. PART NO.

DESCRIPTION

GAIN

42"

Fireplace

37 

1

/

2

"

F0895

F0881

12-8DM

12-8HT

Pipe Section

10 

5

/

8

"

F0896

F0882

18-8DM

18-8HT

Pipe Section

16 

5

/

8

"

F0897

F0883

24-8DM

24-8HT

Pipe Section

23 

5

/

8

"

F0898

F0884

36-8DM

36-8HT

Pipe Section

34 

5

/

8

"

F0899

F0885

48-8DM

48-8HT

Pipe Section

46 

5

/

8

"

F0916

RT-8DM

Round Termination

7

/

8

"*

RTL-8DM

Round Termination

3

/

4

"*

F0918

RLT-8DM

Round Termination

1

/

2

"*

F0917

RTT-8DM

Round Termination with 

Slip Section

7

/

8

" to 

23 

1

/

8

"*

RTTL-8DM

Round Termination with 

Slip Section

1

/

2

" to  

21 

1

/

2

"*

F0919

RLTT-8DM

Round Termination with 

Slip Section

1

/

2

" to  

21 

1

/

4

"*

F0920

ET-8DM

Square Chase-Top

12"*

F0922

ETO-8DM

Square Chase-Top with 

Mesh

12"*

F0921

ETL-8DM

Square Chase-Top with 

Slip Section

7" to 15"*

F0923

ETLO-8DM

Square Chase-Top with 

Mesh & Slip Section

12" to  

25 

1

/

2

"*

* The lineal gain for the terminations is measured to the flue gas 

outlet height.

Summary of Contents for WCT2042WS

Page 1: ...s appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes WARNING If the information in these instructions is not...

Page 2: ...nufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local bu...

Page 3: ...treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide...

Page 4: ...STIBLE COMBUSTIBLE WALL BOARD 0 TO MATERIAL NO COMBUSTIBLE MATERIAL ON FACE GAS LINE KNOCK OUT AIR KIT KNOCK OUTS ROUND TOP TERMINATION GAS LINE KNOCK OUTS LEFT SIDE RIGHT SIDE NOT LESS THAN 14 TO PER...

Page 5: ...d slide unit back until nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be pla...

Page 6: ...625 Max 33 8 MANTELS A mantel may be installed if desired see Figure 4 Woodwork such as wood trims mantels or any other combustible material projecting from front face must not be placed within 9 of...

Page 7: ...cal Cover Plate and Electrical Bushing Fireplace Chassis Ground To Power Source Receptacle Supplied Power Source Wiring Not Supplied Prewired Receptacle and Ground Sheet Metal Screws Figure 7 Outside...

Page 8: ...ONLY by the fireplace must not exceed 20 feet Chimney heights above 20 feet must be supported USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combinations of 12 18 24 36 and 48...

Page 9: ...Straps Detail A Return Elbow Detail B Angle Firestop See Detail A See Detail B Ceiling Support Pipe 12S 8DM VENTING INSTALLATION Continued Return Elbow Offset Elbow Offset Elbow Return Elbow Offset E...

Page 10: ...ectangular opening must be cut 1 Determine center point where pipe will penetrate the roof 2 Determine center point of the roof Pitch is the distance the roof drops over a given span usually 12 A 6 12...

Page 11: ...ply waterproof caulk around perimeter of collar to provide a proper seal Figure 16 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor Fireplace system must be...

Page 12: ...shroud is to be installed contact manufacturer for specifications 24 Min 24 Min 18 Min Typ Figure 18 Multiple Chase Installation 10 2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 19 10 Fo...

Page 13: ...ent Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap...

Page 14: ...rther operating guidelines instructions and warranty informa tion please refer to your homeowner s guide or contact your dealer GLASS DOORS Glass doors are optional with this fireplace When fireplace...

Page 15: ...pplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always g...

Page 16: ...PARTS WOOD BURNING FIREPLACE MODELS WRT2042WS WRT2042WSI WCT2042WS WCT2042WSI 11 27 30 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 13 8 26 6 29 19 21 MODEL CAT NO WRT2042WS F0687 WRT2042WSI...

Page 17: ...m 1 10 108298 01 Front Face Weldment Smooth 1 108298 02 Front Face Weldment Louvered 1 11 106971 01 Left Side Brick Liner 1 12 108310 01 Rear Brick Liner 1 13 106970 01 Right Side Brick Liner 1 14 108...

Page 18: ...Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Se...

Page 19: ...ered Screen ROUND TOP TERMINATIONS WITH LOUVERS W SLIP SECTION F0919 RLTT 8DM Round Top with Slip Section Louvers F0891 RLTT 8HT Hi Temp Round Top w Lvrd Screen and Slip Section SQUARE TOP TERMINATION...

Page 20: ...Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For Use With Chimney Heights In Exces...

Page 21: ...______ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________...

Page 22: ...______ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________...

Page 23: ...ust be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products wi...

Page 24: ...ecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126631 01 Rev B 05 2015 P126631 01 1508 Elm Hill Pike Suite 108 Nashville TN 3...

Reviews: