Superior WCT2042WS Installation And Operation Instructions Manual Download Page 14

Superiorfireplaces.US.com

126631-01B

14

Figure 23 - Glass Doors

Figure 24 - Damper Handle Location

Cleaning Glass

Clean glass with any commercial glass cleaner or soap and water. 

Do not use any abrasive material to clean the glass. Do not clean 

glass with any cool water if glass is still hot from fire and smoke.

DAMPER HANDLE OPERATION

Damper handle, which opens and closes damper blade, is located 

inside firebox at center towards back wall (see Figure 24). Pushing 

handle back into keyway slot will free damper blade to automatically 

open. To close, push handle back into keyhole slot then pull down 

and forward to lock it in place (see Figure 25).Vent damper must be 

locked in the full open position before operating fireplace.

OPERATION AND MAINTENANCE

 WARNING: Risk of fire! Replace grate with IHP 

model 107001-02 only. This grate has been designed to 

keep the operation of your fireplace safe and efficient.

Damper 

Handle

Doors Fully Closed

Doors Fully Opened

1

2

3

1

2

3

Damper 

Weight

To Close Damper

To Open Damper

Figure 25 - Damper Rod

Fireplace Front

Fireplace Front

Figure 26 - Locating Access Cover Plate

Access 

Panel

LOCATING ACCESS COVER PLATE

Sheet metal cover plates located underneath front hearth refractory may 

have shifted or moved out of place while fireplace was in transit. These 

cover plates must be kept in the proper location prior to using the fireplace 

(See Figure 26). 

For further operating guidelines, instructions and warranty informa-

tion, please refer to your homeowner's guide or contact your dealer.

GLASS DOORS

Glass  doors  are  optional  with  this  fireplace.  When  fireplace  is  in 

operation, doors must be fully opened or fully closed position only 

or a fire hazard may be created (see Figure 23).
A fireplace equipped with glass doors operates much differently than 

a fireplace with an open front. A fireplace with glass doors has a 

limited amount of air for combustion. Excessive heat within fireplace 

can result if too large a fire is built or if combustion air gate is not 

completely open.
The following tips should be used to assure that both fireplace and 

glass door retain their beauty and function properly. Both the flue 

damper and glass doors must be fully opened before starting a 

fire. This will provide sufficient combustion air and maintain safe 

temperatures in firebox.

IMPORTANT: 

The glass must be allowed to warm slowly and evenly. 

Tempered glass will withstand a gradual temperature rise to 550° 

F, which is more than a normal fire will generate. Such materials as 

pitch/wax laden logs, very dry mill end lumber and large amounts 

of paper or cardboard boxes can create an excessively hot fire and 

should not be burned in this fireplace. Always keep fire back from 

doors and never allow flames to contact glass.

 " WARNING: FIREPLACES EQUIPPED WITH DOORS 

SHOULD BE OPERATED ONLY WITH DOORS FULLY 

OPEN OR DOORS FULLY CLOSED. IF DOORS ARE LEFT 

PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT 

OF THE FIREPLACE OPENING, CREATING RISKS OF 

BOTH FIRE AND SMOKE".

Summary of Contents for WCT2042WS

Page 1: ...s appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes WARNING If the information in these instructions is not...

Page 2: ...nufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local bu...

Page 3: ...treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide...

Page 4: ...STIBLE COMBUSTIBLE WALL BOARD 0 TO MATERIAL NO COMBUSTIBLE MATERIAL ON FACE GAS LINE KNOCK OUT AIR KIT KNOCK OUTS ROUND TOP TERMINATION GAS LINE KNOCK OUTS LEFT SIDE RIGHT SIDE NOT LESS THAN 14 TO PER...

Page 5: ...d slide unit back until nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be pla...

Page 6: ...625 Max 33 8 MANTELS A mantel may be installed if desired see Figure 4 Woodwork such as wood trims mantels or any other combustible material projecting from front face must not be placed within 9 of...

Page 7: ...cal Cover Plate and Electrical Bushing Fireplace Chassis Ground To Power Source Receptacle Supplied Power Source Wiring Not Supplied Prewired Receptacle and Ground Sheet Metal Screws Figure 7 Outside...

Page 8: ...ONLY by the fireplace must not exceed 20 feet Chimney heights above 20 feet must be supported USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combinations of 12 18 24 36 and 48...

Page 9: ...Straps Detail A Return Elbow Detail B Angle Firestop See Detail A See Detail B Ceiling Support Pipe 12S 8DM VENTING INSTALLATION Continued Return Elbow Offset Elbow Offset Elbow Return Elbow Offset E...

Page 10: ...ectangular opening must be cut 1 Determine center point where pipe will penetrate the roof 2 Determine center point of the roof Pitch is the distance the roof drops over a given span usually 12 A 6 12...

Page 11: ...ply waterproof caulk around perimeter of collar to provide a proper seal Figure 16 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor Fireplace system must be...

Page 12: ...shroud is to be installed contact manufacturer for specifications 24 Min 24 Min 18 Min Typ Figure 18 Multiple Chase Installation 10 2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 19 10 Fo...

Page 13: ...ent Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap...

Page 14: ...rther operating guidelines instructions and warranty informa tion please refer to your homeowner s guide or contact your dealer GLASS DOORS Glass doors are optional with this fireplace When fireplace...

Page 15: ...pplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always g...

Page 16: ...PARTS WOOD BURNING FIREPLACE MODELS WRT2042WS WRT2042WSI WCT2042WS WCT2042WSI 11 27 30 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 13 8 26 6 29 19 21 MODEL CAT NO WRT2042WS F0687 WRT2042WSI...

Page 17: ...m 1 10 108298 01 Front Face Weldment Smooth 1 108298 02 Front Face Weldment Louvered 1 11 106971 01 Left Side Brick Liner 1 12 108310 01 Rear Brick Liner 1 13 106970 01 Right Side Brick Liner 1 14 108...

Page 18: ...Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Se...

Page 19: ...ered Screen ROUND TOP TERMINATIONS WITH LOUVERS W SLIP SECTION F0919 RLTT 8DM Round Top with Slip Section Louvers F0891 RLTT 8HT Hi Temp Round Top w Lvrd Screen and Slip Section SQUARE TOP TERMINATION...

Page 20: ...Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For Use With Chimney Heights In Exces...

Page 21: ...______ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________...

Page 22: ...______ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________...

Page 23: ...ust be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products wi...

Page 24: ...ecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126631 01 Rev B 05 2015 P126631 01 1508 Elm Hill Pike Suite 108 Nashville TN 3...

Reviews: