20

ACCESSORIES 

Continued

IMPORTANT NOTICE

A manufactured shroud which 

has been approved by a na-

tional testing agency for use 

with this fireplace may be used 

if installed in accordance with 

the instructions by its manu-

facturer. A locally fabricated 

shroud may be used with IHP 

Shroud Leg Spacer Kit (SLK) 

in accordance with instructions 

provided with the shroud.

IMPORTANT NOTICE

When penetrating a ceiling 

into an attic, a firestop thimble 

(38FST or FST30) is required 

to avoid intrusion by insulation 

and recommended to negotiate 

a joist.

Thimble 38FST 

or FST 30

Firestop

Canadian code CAN/ULC-S610-M87 and other pertinent 

codes require stainless steel chimney for the installation 

of this fireplace. A Cold Air Climate Kit is also required 

in Canada and is recommended for cooler regions in the 

United States. Below, find a list of approved stainless 

steel parts.

Chimney Parts List for Canada

Catalog 

No.

Model No. 8" Hi-Temp  

Wood burning Chimney

F0881

12-8HT

12" Section Hi-Temp Double 

Wall Pipe Snap Lock

F0882

18-8HT

18" Section Hi-Temp Double 

Wall Pipe Snap Lock

F0883

24-8HT

24" Section Hi-Temp Double 

Wall Pipe Snap Lock

F0884

36-8HT

36" Section Hi-Temp Double 

Wall Pipe Snap Lock

F0885

48-8HT

48" Section Hi-Temp Double 

Wall Pipe Snap Lock

F0886

30E-8HT

30 Degree Hi-Temp Offset 

and Return

F0887

12S-8HT

Hi-Temp Chimney Support 

(For Use With Chimney 

Heights In Excess of 30')

F0888

RT-8HT

Hi-Temp Round Top with 

Mesh Screen

F0889

RTT-8HT

Hi-Temp Round Top with 

Mesh Screen and Slip Sec-

tion

F0890

RLT-8HT

Hi-Temp Round Top with 

Louvered Screen

F0891

RLTT-8HT

Hi-Temp Round Top with 

Louvered Screen and Slip 

Section

F0892

ET-8HT

Hi-Temp Pyramid Top with 

Slip Section

F0893

ETL-8HT

Hi-Temp Large Pyramid Top 

with Slip Section (use with all 

8" systems)

F0894

AP-8HT

Hi-Temp Anchor Plate/Col

-

lar Assembly (for masonry 

fireplaces)

F0929

CAK-8

Cold Air Collar Kit - 8" 

Chimney

*When ordered alone, this part cannot ship via parcel 

delivery services.

NOTICE: The firebox canopy (hood) 

must not be modified or replaced with 

a canopy that may be provided with 

the unvented decorative room heater.

CAUTION: THE STRUCTURAL INTEG-

RITY OF THE MANUFACTURED HOME 

FLOOR, WALL, AND CEILING/ROOF 
MUST BE MAINTAINED.

 

 

WARNING: DO NOT INSTALL 

IN SLEEPING ROOM OF MOBILE 

HOMES.

 WARNING: Discontinue use 

of the appliance immediately if 

doors are damaged and contact 

a qualified installer for repair. 

Only doors certified with the 

appliance shall be used.

 WARNING: Do not slam or 

strike doors. Damage can result 

in a hazardous condition.

FAN KIT

F1083

BK3

3-Blade Fan 

BLOWER KIT

F1081

BK

Manual Fan, Variable Speed

Summary of Contents for WCT2042WS

Page 1: ...s appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes WARNING If the information in these instructions is not...

Page 2: ...nufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local bu...

Page 3: ...treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide...

Page 4: ...STIBLE COMBUSTIBLE WALL BOARD 0 TO MATERIAL NO COMBUSTIBLE MATERIAL ON FACE GAS LINE KNOCK OUT AIR KIT KNOCK OUTS ROUND TOP TERMINATION GAS LINE KNOCK OUTS LEFT SIDE RIGHT SIDE NOT LESS THAN 14 TO PER...

Page 5: ...d slide unit back until nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be pla...

Page 6: ...625 Max 33 8 MANTELS A mantel may be installed if desired see Figure 4 Woodwork such as wood trims mantels or any other combustible material projecting from front face must not be placed within 9 of...

Page 7: ...cal Cover Plate and Electrical Bushing Fireplace Chassis Ground To Power Source Receptacle Supplied Power Source Wiring Not Supplied Prewired Receptacle and Ground Sheet Metal Screws Figure 7 Outside...

Page 8: ...ONLY by the fireplace must not exceed 20 feet Chimney heights above 20 feet must be supported USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combinations of 12 18 24 36 and 48...

Page 9: ...Straps Detail A Return Elbow Detail B Angle Firestop See Detail A See Detail B Ceiling Support Pipe 12S 8DM VENTING INSTALLATION Continued Return Elbow Offset Elbow Offset Elbow Return Elbow Offset E...

Page 10: ...ectangular opening must be cut 1 Determine center point where pipe will penetrate the roof 2 Determine center point of the roof Pitch is the distance the roof drops over a given span usually 12 A 6 12...

Page 11: ...ply waterproof caulk around perimeter of collar to provide a proper seal Figure 16 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor Fireplace system must be...

Page 12: ...shroud is to be installed contact manufacturer for specifications 24 Min 24 Min 18 Min Typ Figure 18 Multiple Chase Installation 10 2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 19 10 Fo...

Page 13: ...ent Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap...

Page 14: ...rther operating guidelines instructions and warranty informa tion please refer to your homeowner s guide or contact your dealer GLASS DOORS Glass doors are optional with this fireplace When fireplace...

Page 15: ...pplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always g...

Page 16: ...PARTS WOOD BURNING FIREPLACE MODELS WRT2042WS WRT2042WSI WCT2042WS WCT2042WSI 11 27 30 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 13 8 26 6 29 19 21 MODEL CAT NO WRT2042WS F0687 WRT2042WSI...

Page 17: ...m 1 10 108298 01 Front Face Weldment Smooth 1 108298 02 Front Face Weldment Louvered 1 11 106971 01 Left Side Brick Liner 1 12 108310 01 Rear Brick Liner 1 13 106970 01 Right Side Brick Liner 1 14 108...

Page 18: ...Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Se...

Page 19: ...ered Screen ROUND TOP TERMINATIONS WITH LOUVERS W SLIP SECTION F0919 RLTT 8DM Round Top with Slip Section Louvers F0891 RLTT 8HT Hi Temp Round Top w Lvrd Screen and Slip Section SQUARE TOP TERMINATION...

Page 20: ...Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For Use With Chimney Heights In Exces...

Page 21: ...______ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________...

Page 22: ...______ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________...

Page 23: ...ust be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products wi...

Page 24: ...ecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126631 01 Rev B 05 2015 P126631 01 1508 Elm Hill Pike Suite 108 Nashville TN 3...

Reviews: