background image

Superiorfireplaces.US.com

126631-01B

11

VENTING INSTALLATION 

Continued

Pitch

Slope Opening 

"A" Max. 

Used Flashing 

Model No. 

Flat

15"

V6F-8DM

0-6/12

26.6°

16 

1

/

8

"

V6F-8DM

6/12- 12/12 45.0°

20 

3

/

8

"

V12F-8DM

Figure 14 - Roof Opening Measurements

FLASHING INSTALLATION (V6F-8DM OR V12F-8DM)

Determine flashing to be used with roof opening chart. Slide flashing 

over pipe until base is flat against roof. Replace as many shingles as 

needed to cover exposed area and flashing base. Secure in position 

by nailing through shingles (see Figure 15). DO NOT NAIL THROUGH 

FLASHING CONE.

Installing Flashing on a Metal Roof

When installing flashing on a metal roof, it is required that putty tape 

be used between flashing and roof. Flashing must be secured to roof 

using #8 x 3/4" screws and then sealed with roof coating to prevent 

leakage through screw holes. A roof coating must also be applied 

around perimeter of flashing to provide a proper seal.

Nail Only Outer 

Perimeter of 

Flashing

Storm Collar

Underlap Shingles 

at Bottom

Figure 15 - Flashing Installation

Flashing 

Cone

Overlap 

Shingles Top 

and Sides Only

Storm Collar Installation (SC1)

Place storm collar over pipe and slide down until it is snug against 

open edge of flashing (see Figure 16). Use SC1 for all round termina

-

tions. Apply waterproof caulk around perimeter of collar to provide 

a proper seal.

Figure 16 - Storm Collar

Chimney 

Pipe

Waterproof 

Caulk

Storm 

Collar

Flashing

Terminations/Spark Arrestor

Fireplace system must be terminated with listed round top or chase 

terminations. In any case, refer to installation instructions supplied 

with termination. Terminations approved for this fireplace are RT-

8DM, RTL -8DM and RLT-8DM that can be used for flashing or chase 

and ET-8DM, ETO-8DM, ETL-8DM and ETLO-8DM for chase style ter

-

mination only. Figure 17 shows an RTL-8DM round top termination.

 CAUTION: Do not seal openings on the rooftop 

flashing. Follow the installation instructions provided 

with the termination being used.

Terminations  with  16"  slip  pipe  sections  are  available.  RTT-8DM, 

RTTL-8DM and RLTT-8DM are approved for flashing installations. 

When needed, these adjustable terminations may be used in combina-

tion with pipe assembly to achieve correct chimney height.

Note:

 In the rare instance there is a problem with side driven rain or 

wind or chimney is not drafting properly, an ADS-8DM (Anti-Draft 

Shield) can be used with round terminations.

Attach Bracket 

Tabs to 

Outer Pipe 

(3 Places) 

Secure with 

Screws

RTL-8DM

Level of Flue 

Gas Outlet

Caulk

Collar

Flashing

Underlap Shingles 

Bottom Only

Figure 17 - Termination

Overlap 

Shingles Top 

and Sides

Flue Pipe of 

RTL-8DM 

Inside Inner 

Pipe of 

Chimney

30"

(76.2 cm)

Minimum Measurements

Opening "A"

14 

3

/

8

"

(48.3 cm)

1"

(2.54

cm)

1"

(2.54

cm)

1"

(2.54 cm)

Summary of Contents for WCT2042WS

Page 1: ...s appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes WARNING If the information in these instructions is not...

Page 2: ...nufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local bu...

Page 3: ...treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide...

Page 4: ...STIBLE COMBUSTIBLE WALL BOARD 0 TO MATERIAL NO COMBUSTIBLE MATERIAL ON FACE GAS LINE KNOCK OUT AIR KIT KNOCK OUTS ROUND TOP TERMINATION GAS LINE KNOCK OUTS LEFT SIDE RIGHT SIDE NOT LESS THAN 14 TO PER...

Page 5: ...d slide unit back until nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be pla...

Page 6: ...625 Max 33 8 MANTELS A mantel may be installed if desired see Figure 4 Woodwork such as wood trims mantels or any other combustible material projecting from front face must not be placed within 9 of...

Page 7: ...cal Cover Plate and Electrical Bushing Fireplace Chassis Ground To Power Source Receptacle Supplied Power Source Wiring Not Supplied Prewired Receptacle and Ground Sheet Metal Screws Figure 7 Outside...

Page 8: ...ONLY by the fireplace must not exceed 20 feet Chimney heights above 20 feet must be supported USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combinations of 12 18 24 36 and 48...

Page 9: ...Straps Detail A Return Elbow Detail B Angle Firestop See Detail A See Detail B Ceiling Support Pipe 12S 8DM VENTING INSTALLATION Continued Return Elbow Offset Elbow Offset Elbow Return Elbow Offset E...

Page 10: ...ectangular opening must be cut 1 Determine center point where pipe will penetrate the roof 2 Determine center point of the roof Pitch is the distance the roof drops over a given span usually 12 A 6 12...

Page 11: ...ply waterproof caulk around perimeter of collar to provide a proper seal Figure 16 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor Fireplace system must be...

Page 12: ...shroud is to be installed contact manufacturer for specifications 24 Min 24 Min 18 Min Typ Figure 18 Multiple Chase Installation 10 2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 19 10 Fo...

Page 13: ...ent Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap...

Page 14: ...rther operating guidelines instructions and warranty informa tion please refer to your homeowner s guide or contact your dealer GLASS DOORS Glass doors are optional with this fireplace When fireplace...

Page 15: ...pplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always g...

Page 16: ...PARTS WOOD BURNING FIREPLACE MODELS WRT2042WS WRT2042WSI WCT2042WS WCT2042WSI 11 27 30 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 13 8 26 6 29 19 21 MODEL CAT NO WRT2042WS F0687 WRT2042WSI...

Page 17: ...m 1 10 108298 01 Front Face Weldment Smooth 1 108298 02 Front Face Weldment Louvered 1 11 106971 01 Left Side Brick Liner 1 12 108310 01 Rear Brick Liner 1 13 106970 01 Right Side Brick Liner 1 14 108...

Page 18: ...Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Se...

Page 19: ...ered Screen ROUND TOP TERMINATIONS WITH LOUVERS W SLIP SECTION F0919 RLTT 8DM Round Top with Slip Section Louvers F0891 RLTT 8HT Hi Temp Round Top w Lvrd Screen and Slip Section SQUARE TOP TERMINATION...

Page 20: ...Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For Use With Chimney Heights In Exces...

Page 21: ...______ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________...

Page 22: ...______ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________...

Page 23: ...ust be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products wi...

Page 24: ...ecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126631 01 Rev B 05 2015 P126631 01 1508 Elm Hill Pike Suite 108 Nashville TN 3...

Reviews: