NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
19
Step 14. HOOD INSTALLATION
(Refer to Figure 35)
All of these appliances must have a hood
installed prior to operating.
Slide the hood into the slots on the lower edge
of the cabinet top
.
FINISHING REQUIREMENTS -
Wall Details
Complete fi nished interior wall. To install the
appliance facing fl ush with the fi nished wall,
position framework to accommodate the thick-
ness of the fi nished wall (
Figure 35
).
See Page 5 for Cold Climate Insulation
and Page 6 for Clearances
5
- Replace the switch.
6
- Reinstall the switch/bracket assembly.
7
- Reinstall the scoop and lintel.
8
- Reinstall the glass enclosure panel.
9
- Reinstall the bottom control compartment
access panel and the top louver panel.
10 -
The appliance should then relight and
remain lit. If this does not occur, check
unit for a blocked fl ue condition.
Blocked Flue Safety Limit Location - See
Figures 32, 33 & 34
. Inside View of Firebox
- Top/Right Side Intersection
Figure 32
Figure 34
Figure 33
Combustible
Wall
Framing
Combustible
Finished Wall
Materials
Top of Appliance
Louvers
Top of Door
Frame
Hood must
be installed
as shown.
1 in. Min.
(25 mm)
Top
Spacers
Figure 35
Finishing Requirements
Remote Control Kit, Standard
Cat. No.
Model No.
Description
H0249
RCL
Remote Control System
White Wall Switch Kit
Cat. No.
Model No.
Description
85L87
FWSK
OFF/ON Wall Switch Kit
Rocker Switch Kit
Cat. No.
Model No.
Description
80L41
FRS
Rocker Switch Kit
Outside Combustion Air Kits
Cat. No.
Model No.
Description
81L87
FOAK-4
Combustion Air Kit (w/duct)
81L88
FOAK-4LD
Combustion Air Kit (w/o duct)
INSTALLATION ACCESSORIES
The following accessory items are available
for use in the installation of these appliances.
See Homeowners Manual for a complete list of
accessories and more detailed information on
the following installation accessories:
Forced Air Blower Kits
Cat.
No.
Model No.
Description
80L84
FBK-100
Blower, Standard
(single speed)
80L85
FBK-200
Blower, Variable Speed
(w/wall-mounted switch)
80L86
FBK-250
Blower, Variable Speed
(w/unit-mounted switch)
94L89
FBK-100-36
Blower, Standard, 36 Pack
94L90
FBK-200-36
Blower - Variable, 36 Pack
H0543
FBK-250-36
Blower - Variable, 36 Pack
Wire
Terminals
Cabinet
Corner
Back of Spill
Switch (high
limit disc)
Firebox
Top
Door
Frame
Lintel Securing Screw
Hole in Cabinet Top
Scoop Securing Screws
Scoop
Firebox
Top
Lintel Securing Screw
Hole in Cabinet Top
Spill Switch (limit disc)
Combustible
material may
touch the appli-
ance top
View Without Scoop
Spill Switch (limit disc)
Bracket Securing Screws
GAS CONVERSION KITS
Millivolt
SIT Systems
Propane to Natural Gas
Conversion Kits
Models
Cat. No.
SSBV-3530
85L66
SSBV-4035
85L67
Millivolt
HONEYWELL Systems
Natural Gas To Propane Gas
Conversion Kits
Models
Cat. No.
SSBV-3530
11M37
SSBV-4035
11M38
Electronic
HONEYWELL Systems
Natural Gas To Propane Gas
Conversion Kits
Models
Cat. No.
SSBV-3530
85L73
SSBV-4035
85L74
Millivolt
SIT Systems
Natural Gas To Propane Gas
Conversion Kits
Models
Cat. No.
SSBV-3530
85L59
SSBV-4035
85L60
Millivolt
HONEYWELL Systems
Propane Gas To Natural Gas
Conversion Kits
Models
Cat. No.
SSBV-3530
11M34
SSBV-4035
11M35
Electronic
HONEYWELL Systems
Propane Gas To Natural Gas
Conversion Kits
Models
Cat. No.
SSBV-3530
85L80
SSBV-4035
85L81
f i r e - p a r t s . c o m