background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

20

SIT Millivolt Gas Valve

Pressure

Regulator

Remove 
These 
Components

Figure 36

Gas conversion kits are available to adapt the 
appliance from the use of one type of gas to 
the use of another. These kits contain all the 
necessary components needed to complete the 
task including labeling that must be affi xed to 
ensure safe operation.

Kit part numbers are listed here and the following 
steps detail the conversion procedure. 

Step 1. 

Turn off the gas supply to the appliance. 

Remove the front glass door/frame from the 
appliance. Access the control compartment.

Step 2. 

Carefully remove the logs. Exercise care 

so as not to break the logs.

Step 3. Locate the screws securing the burner 

assembly to the appliance.  Remove the burner 
assembly and retain the securing screws.

Step 4. Millivolt Appliances - SIT Systems

a. See 

Figure 36

  and the instructions 

provided with the kit.  Using a Torx T20, 
tool or  or standard fl at screwdriver remove 
and discard the three pressure regulator 
mounting screws.  Remove the pressure 
regulator, spring, poppet, diaphragm and 
bushing.  Discard all removed components.  
Ensure the rubber gasket installed on the 
back of the replacement pressure regulator 
is properly positioned and install the new 
pressure regulator using the new screws 
supplied with the kit.  Tighten screws to 25 
In. lb. torque.

            

WARNING

This conversion kit shall be 
installed by a qualifi ed service 
agency in accordance with the 
manufacturer's instructions and 
all applicable codes and require-
ments of the authorized having 
jurisdiction.  If the information 
in these instructions is not fol-
lowed exactly, a fi re, explosion 
or production of carbon monox-
ide may result causing property 
damage, personal injury or loss 
of life.  The installation is not 
proper and complete until the 
operation of the converted appli-
ance is checked as specifi ed in 
the owner instructions supplied 
with the kit. The qualifi ed service 
agency performing this installa-
tion assumes responsibility for 
this conversion.

                 

IMPORTANT

CANADA ONLY

The conversion shall be carried 
out in accordance with the require-
ments of the provincial authorities 
having jurisdiction and in accor-
dance with the requirements of 
the CAN1-B149.1 And B149.2 
Installation code.

         IMPORTANT 

LE CANADA SEULEMENT

La conversion devra être effec-
tuée conformément aux recom-
mandations des autorités pro-
vinciales ayant juridiction et 
conformément aux exigences du 
code d'installation CAN1-B149.1 
ET.2.

            

AVERTISSEMENT

Cet équipement de conversion 
sera installé par une agence 
qualifi ée de service conformé-
ment aux instructions du fabri-
cant et toutes exigences et codes 
applicables de l'autorisés avoir 
la juridiction.  Si l'information 
dans cette instruction n'est pas 
suivie exactement, un feu, explo-
sion ou production de protoxyde 
de carbone peut résulter le 
dommages causer de propriété, 
perte ou blessure personnelle 
de vie.  L'agence qualifiée 
de service est esponsable de 
l'installation propre de cet 
équipment.  L'installation n'est 
pas propre et compléte jusqu'à 
l'opération de l'appareil converti 
est chéque suivant les critères 
établis dans les instructions de 
propriétaire provisionnées avec 
l'équipement.

f i r e - p a r t s . c o m

Summary of Contents for SSBV-3530CNE

Page 1: ...le home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certif...

Page 2: ...Misc Codes Standards TheInstallationmustconformtolocalcodesor in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or the Natural Gas and Propane Instal lat...

Page 3: ...as Valve Electronic Models Electronic models have a fixed rate gas valve Input of electronic models is shown in Table 3 MASSACHUSETTS REQUIREMENTS Theseappliancesareapprovedforinstallationin the follo...

Page 4: ...i fication or alteration may void the warranty certification and listings of this unit WARNING Carbon monoxide poisoning early signs of carbon monoxide poisoning are similar to the flu withheadaches d...

Page 5: ...n If the fireplace is being installed on a cement slab in cold climates a sheetofplywoodorotherraisedplatformcanbe placedunderneathtopreventconductingcoldup into the room It also helps to sheetrock in...

Page 6: ...rmation and consult your local building code to determine if you need additional support If you plan to raise the fireplace and hearth extension build the platform assembly then position fireplace and...

Page 7: ...7 Vertical Vent Termination Clearances Roof Pitch is X 12 Minimum Height from Roof to Lowest Discharge Opening X 12 1 25 mm Minimum Note Venting terminals shall not be recessed into a wall or siding G...

Page 8: ...Finishing Materials if any Rough Framing Face Unfinished Shown Optional FOAK Outside Air Kit A Outside Chase G C J Back Wall of Chase Enclosure Including Finishing Materials if any Rough Framing Face...

Page 9: ...maximum overall height of the vent system and appliance should not exceed 40 feet Install the B vent system in accordance with the vent manufacturer s instructions Figure 13 1 25 mm Minimum Firestop S...

Page 10: ...tionalfield providedjunctionboxwithrecep tacle may be installed at the front of the control compartment on either side of the cabinet See Figure 16 It will be held in place by a conduit fitting and lo...

Page 11: ...safetyhazard Theappliancemustbe electrically grounded in accordance withlocalcodesor intheabsenceof local codes the National Electrical Code ANSI NFPA 70 latest edition In Canada the current CSA C22...

Page 12: ...ator through several cycles including the closed position Ensuring proper operation and freedom of movement Return the actuator arm to the closed position Outside Air Control Lever and Securing Screw...

Page 13: ...t Lightinginstructionslabel can be found in the control compartment see Figure 20 When first lighting the appliance it will take a few minutes for the line to purge itself of air Once purging is compl...

Page 14: ...o 1 5 Place the top left log B as shown The top forkonlog B fitsintonotchonlog A The bottom of the log rests on the subfloor SSBV 3530 Install as Follows Carefully position the ceramic fiber logs into...

Page 15: ...ere 1through5 andper theinstructionson Page14 A Notch Notch 2 C 3 Notchesonbottomoflog C fitsover2locatingbrackets Topforkonlog B fitsintonotchonlog A B A 4 D A 5 Topforkonlog D fitsintonotchonlog A P...

Page 16: ...1through5 andper theinstructionson Page14 D A 4 A Bottomoflog B restsonsubfloor B Topforkonlog D fitsintonotchonlog A asshown Topforkonlog B fitsintonotchonlog A as shown 1 PlaceEmbers andVolcanicSto...

Page 17: ...ng black tip the air shutter opening may need to be adjusted Iftheairshutteropeningsclosedtoofar sooting maydevelop Sootingisindicatedbyblackpuffs developingatthetipsofverylongorangeflames Sootingresu...

Page 18: ...nting action start by holding a smoke producing device within an inch of one edge side edge not top or bottom edge of one glass enclosure panel The smoke should be drawn toward the edge of the glass e...

Page 19: ...FOAK 4LD Combustion Air Kit w o duct INSTALLATION ACCESSORIES The following accessory items are available for use in the installation of these appliances See Homeowners Manual for a complete list of a...

Page 20: ...cablecodesandrequire ments of the authorized having jurisdiction If the information in these instructions is not fol lowed exactly a fire explosion or production of carbon monox ide may result causing...

Page 21: ...ntactingtheorificestripcouldcause stripdistortionrenderingthepilotinop erative Also avoid wrench contact to any of the other pilot parts Use a 7 16 open end wrench and turn the pilot hex fitting count...

Page 22: ...he Igniter assembly use extreme care to prevent damage and break age Do not apply any leverage to the Igniter assembly while restoring the retainer clip to its original position All Models Step 8 Remo...

Page 23: ...23 NOTE THIS PAGE LEFT BLANK INTENTIONALLY fire parts com...

Page 24: ...th Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor fo...

Reviews: