![Superior FCN1590 Operator'S Manual Download Page 11](http://html.mh-extra.com/html/superior/fcn1590/fcn1590_operators-manual_1402970011.webp)
FRANÇAIS
ENGLISH
11
MAINTENANCE
CAUTION:
Disconnect tool from air supply before
cleaning and inspecting the tool. Correct all problems
before operating.
CLEAN AND INSPECT DAILY
n
Add pneumatic tool oil into the oiler regularly to
assure that all moving. Frequent, but not exces-
sive lubrication is required for the best perfor-
mance. Oil added through the air line connection
will lubricate the inside parts. An automatic oiler
is recommended, but 2 drops of oil may be added
manually into the tool’s air intake at the male
quick-connect fitting (
F, fig.1
) at the beginning
of each workday and after about every hour of
continuous use. Only a few drops at a time are
necessary. More than this will pool inside the tool
and be expelled from the tool’s exhaust during
firing. USE ONLY PNEUMATIC TOOL OIL. Do
not use detergent oil or oil with other additives, as
these can cause accelerated wear on the seals.
n
Check the filter of the compressor weekly.
Open drain cock to drain all water and contami-
nants out of the air tank.
n
Wipe the tool clean.
n
Blow the tool clean using high compressed air,
and then use non-flammable cleaning solutions to
wipe exterior of tool if necessary.
n
Do not soak tool in cleaning solutions. Such solu-
tions can damage internal parts. The exposed
portion of the small piston rod and feed hook must
be kept clean.
n
Inspect trigger and safety mechanism daily to as-
sure system is complete and functional.
n
Keep all screws tight. Loose screws can cause
personal injury or damage to the tool. Check if
there are worn and damaged parts. If any, please
replace immediately.
TROUBLESHOOTING
WARNING:
Stop using the tool immediately if any
of the following problems occur. Serious personal
injury may result. Any repairs or replacements
must be done by qualified personnel or by an
authorized service centre only.