background image

SuperiorFireplaces.us.com

127020-01_E

3

SAFETY

 Continued

 WARNING: CONTINUED OVERFIRING CAN PER-

MANENTLY DAMAGE YOUR FIREPLACE SYSTEM. 

SOME EXAMPLES OF CONDITIONS THAT COULD 

CAUSE OVERFIRING ARE:

• BURNING QUANTITIES OF SCRAP LUMBER, PINE 

BRANCHES, PAPER OR CARDBOARD BOXES 

WHICH EXCEED THE VOLUME OF THE NORMAL 

LOG FIRE.

• BURNING TRASH, CHEMICALS OR CHEMICALLY 

TREATED COMBUSTIBLES.

Disposal of Ashes 
Ashes should be placed in a metal container with a 

tight-fitting lid. The closed container of ashes should 

be placed on a noncombustible floor or on the ground, 

well away from all combustible materials, pending 

final disposal. If the ashes are disposed of by burial 

in soil or otherwise locally dispersed, they should be 

retained in the closed container until all cinders have 

thoroughly cooled.

WHEN USING THE DECORATIVE APPLIANCE, THE 

FIREPLACE DAMPER MUST BE SET IN THE FULLY 

OPEN POSITION.

Never use gasoline, gasoline-type lantern fuel, kero-

sene, charcoal lighter fluid, or similar liquids to start 

or ’freshen up’ a fire in this fireplace. Keep all such 

liquids well away from the fireplace while it is in use.

Use SOLID WOOD only for fuel. It is best to use dry 

and well seasoned hardwood. Softwoods tend to burn 

very quickly. DO NOT use treated wood, charcoal, coal, 

trash, driftwood or woods that have been dipped in tar, 

pitch, pine tar, creosote, etc. Wood products made 

with synthetic binders, such as plywood, produce ab-

normally high temperatures and sputtering, smoking 

fires.  When burning artificial logs, please read and 

follow the instructions provided by the manufacturer.

Never burn treated construction lumber or scraps. 

These woods burn excessively hot and may contain 

chemicals used to treat insects and fungus. When 

burned, these chemicals can pose a significant hazard.

IMPORTANT: See appendix A, page 21 for additional 

information regarding draft requirements, smoking 

causes and troubleshooting.

 WARNING: BURNING IMPROPER FUEL (I.E. CHAR-

COAL) CAN RESULT IN CARBON MONOXIDE POISON-

ING, WHICH MAY LEAD TO DEATH! 
Carbon Monoxide Poisoning – Early signs of carbon 

monoxide poisoning resemble the flu with headaches, 

dizziness, or nausea. If you have these signs, get 

fresh air at once!  Have the appliance inspected by a 

qualified service technician.  Some people are more af-

fected by carbon monoxide than others.  These include 

pregnant women, people with heart or lung disease 

or anemia, those under the influence of alcohol, and 

those at high altitudes.

Ventilation Requirements - Provide adequate air for 

combustion. The fresh air requirements of this ap-

pliance must be met within the space where it will 

be installed.

Smoke Detectors - Since there are always several 

potential sources of fire in any home, we recommend 

installing smoke detectors. If possible, install the 

smoke detector in a hallway adjacent to the room (to 

reduce the possibility of occasional false activation 

from the heat produced by the appliance).  If your local 

code requires a smoke detector be installed within the 

same room, you must follow the requirements of your 

local code. Check with your local building department 

for requirements in your area.

Creosote – Formation and Need for Removal 

When wood is burned slowly, it produces tar and other 

organic vapors, which combine with expelled mois-

ture to form creosote. The creosote vapors condense 

in the relatively cool chimney flue of a slow-burning 

fire. As a result, creosote residue accumulates on 

the flue lining. When ignited this creosote makes an 

extremely hot fire. 

The chimney shall be inspected at least twice a year 

during the heating season to determine when a creosote 

buildup has occurred.  When creosote has accumulated 

(1/8" [3 mm] or more) it shall be removed to reduce 

the risk of a chimney fire.

Summary of Contents for WRE3036WH

Page 1: ...ADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L au...

Page 2: ...Venting Installation 7 Optional Gas Line Installation 12 Operation and Maintenance Guidelines 13 Technical Service 14 Replacement Parts 14 Important Notices Canada 15 Parts 16 Accessories 18 Draft Sm...

Page 3: ...canposeasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESU...

Page 4: ...9 mm 29 737 mm 41 1042 mm 1 26 mm 1 26 mm 21 534 mm 8 204 mm 35 889 mm 37 940 mm 41 1042 mm 1 26 mm AIRSPACE TO COMBUSTIBLE MATERIAL 0 0 mm TO TOP SPACERS 0 0 mm TO BOTTOM 8 204 mm EACH SIDE NO COMBUS...

Page 5: ...air kit is available with this fireplace see Optional Outside Air Kit on page 7 MINIMUM CLEARANCE TO COMBUSTIBLES Ceiling 40 1016 mm minimum Back and sides of fireplace 3 4 19 mm minimum Floor 0 0 mm...

Page 6: ...concrete metal glass marble stone etc Provide a means to prevent the hearth extension from shifting and seal gap between the fireplace frame and hearth extension with a noncom bustible material see F...

Page 7: ...ability to individual site requirements Actual lengths gained after fitting overlaps must be taken into consideration lineal gain and are given in the lineal gain chart see Figure 6 Lineal gain is the...

Page 8: ...ht above offset rests on return elbow Straps must be securely nailed to rafters or joists see Figure 8 details A and B 3 Maximum length of pipe between supports return elbow or 12S 8DM is 6 of angle r...

Page 9: ...lowasshowninFigure10 They also provide complete separation from one floor space to another or attic space as required by most codes When the double wall pipe passes through a framed opening into an at...

Page 10: ...ny shingles as needed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 13 DO NOT NAIL THROUGH FLASHING CONE Installing Flashing on a Metal Roof When in...

Page 11: ...of that is within a horizontal distance of 10 feet see Figure 17 FINISHING FIREPLACE Combustible materials such as wallboard sheet rock drywall ply wood etc may make direct contact with sides and top...

Page 12: ...d connections must be tested for leaks after the installation is completed After ensuring that the gas valve is on apply soap and water solution to all connections and joints Bubbles formingshowaleak...

Page 13: ...of the appliance imme diately if doors are damaged and contact a qualified installer for repair Only doors certified with the ap pliance shall be used WARNING Do not slam or strike doors Damage can r...

Page 14: ...through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the fireplace...

Page 15: ...all Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT...

Page 16: ...SuperiorFireplaces us com 127020 01_E 16 PARTS 9 24 16 31 25 16 4 30 32 19 12 23 20 28 17 8 1 5 21 2 18 11 14 3 13 22 10 6 29 7 33 34 26 27 15 MODEL CATALOG NO WRE3036WS F0449 WRE3036WH F0450...

Page 17: ...5 Damper Can Collar 1 16 J8012 Kit Screen Assembly 1 17 Firebox Top Assembly 1 18 J3980 Air Kit Door Assembly 1 19 Face Weldment 1 20 J4470 Air Deflector 1 21 Fireplace Top Insulation 1 22 J4052 Acces...

Page 18: ...Her White S36 1 4 Refractory Rear Her White S36 1 5 Refractory Btm Rear White S36 1 6 Refractory Btm Frnt White S36 1 1 2 4 3 6 5 Stacked Refractory Shown ACCESSORIES REFRACTORY STAIN KITS Use the re...

Page 19: ...ection Hi Temp Double Wall Pipe Snap Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double W...

Page 20: ...F0921 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SL...

Page 21: ...electing the proper venting system for your installation American National Standards Institute ANSI NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appli ances See Draft Section...

Page 22: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Page 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Page 24: ...7020 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...