PARTS

This list contains replaceable parts used in your fireplace. When ordering parts, see Replacement Parts on page 14 of this manual.

KEY 

NO.

CATALOG NO. DESCRIPTION

QTY.

1

**

Insulation Pan

1

2

**

Fireplace Top

1

3

**

Fireplace Surround

1

4

J3946

Air Rod Retainer

1

5

J3947

Damper Rod Retainer

1

6

**

Firebox Bottom

1

7

**

Firebox Surround

1

8

**

Air Separator

1

9

See page 18

Left, Refractory Brick Liner

1

10

See page 18

Right, Refractory Brick Liner

1

11

See page 18

Rear, Refractory Brick Liner

1

12

See page 18

Bottom Rear Refractory, Brick Liner

1

13

See page 18

Bottom Front Refractory, Brick Liner

1

14

**

Firebox Support Leg

4

15

**

Damper Can Collar

1

16

J8012

Kit, Screen Assembly

1

17

**

Firebox Top Assembly

1

18

J3980

Air Kit Door Assembly

1

19

**

Face Weldment

1

20

J4470

Air Deflector

1

21

**

Fireplace Top Insulation

1

22

J4052

Access Panel

1

23

J4491

Grate

1

24

**

Collar Insulation

1

25

J6893

Chimney Starter Collar

1

26

J6895

Refractory Retainer

2

27

J3939

Grate Retainer

2

28

J4504

Door Stop

1

29

J4523

Pivot Clip

2

30

J6905

Spring Clip

2

31

J6918

Top Spacer

4

32

J6934

Conduit Plate Cover

4

33

J6951

Gas Conduit

2

34

J6952

Gas Conduit

2

PARTS AVAILABLE NOT SHOWN

106625-01

Home Owner’s Guide

1

J6906

Ember Protector

2

** Not a field replaceable part

 WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved 

by IHP. Use of non-approved parts can result in poor performance and safety hazards.

MODEL

CATALOG NO.

WRE3036WS F0449

WRE3036WH F0450

Summary of Contents for WRE3036WH

Page 1: ...ADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L au...

Page 2: ...Venting Installation 7 Optional Gas Line Installation 12 Operation and Maintenance Guidelines 13 Technical Service 14 Replacement Parts 14 Important Notices Canada 15 Parts 16 Accessories 18 Draft Sm...

Page 3: ...canposeasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESU...

Page 4: ...9 mm 29 737 mm 41 1042 mm 1 26 mm 1 26 mm 21 534 mm 8 204 mm 35 889 mm 37 940 mm 41 1042 mm 1 26 mm AIRSPACE TO COMBUSTIBLE MATERIAL 0 0 mm TO TOP SPACERS 0 0 mm TO BOTTOM 8 204 mm EACH SIDE NO COMBUS...

Page 5: ...air kit is available with this fireplace see Optional Outside Air Kit on page 7 MINIMUM CLEARANCE TO COMBUSTIBLES Ceiling 40 1016 mm minimum Back and sides of fireplace 3 4 19 mm minimum Floor 0 0 mm...

Page 6: ...concrete metal glass marble stone etc Provide a means to prevent the hearth extension from shifting and seal gap between the fireplace frame and hearth extension with a noncom bustible material see F...

Page 7: ...ability to individual site requirements Actual lengths gained after fitting overlaps must be taken into consideration lineal gain and are given in the lineal gain chart see Figure 6 Lineal gain is the...

Page 8: ...ht above offset rests on return elbow Straps must be securely nailed to rafters or joists see Figure 8 details A and B 3 Maximum length of pipe between supports return elbow or 12S 8DM is 6 of angle r...

Page 9: ...lowasshowninFigure10 They also provide complete separation from one floor space to another or attic space as required by most codes When the double wall pipe passes through a framed opening into an at...

Page 10: ...ny shingles as needed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 13 DO NOT NAIL THROUGH FLASHING CONE Installing Flashing on a Metal Roof When in...

Page 11: ...of that is within a horizontal distance of 10 feet see Figure 17 FINISHING FIREPLACE Combustible materials such as wallboard sheet rock drywall ply wood etc may make direct contact with sides and top...

Page 12: ...d connections must be tested for leaks after the installation is completed After ensuring that the gas valve is on apply soap and water solution to all connections and joints Bubbles formingshowaleak...

Page 13: ...of the appliance imme diately if doors are damaged and contact a qualified installer for repair Only doors certified with the ap pliance shall be used WARNING Do not slam or strike doors Damage can r...

Page 14: ...through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the fireplace...

Page 15: ...all Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT...

Page 16: ...SuperiorFireplaces us com 127020 01_E 16 PARTS 9 24 16 31 25 16 4 30 32 19 12 23 20 28 17 8 1 5 21 2 18 11 14 3 13 22 10 6 29 7 33 34 26 27 15 MODEL CATALOG NO WRE3036WS F0449 WRE3036WH F0450...

Page 17: ...5 Damper Can Collar 1 16 J8012 Kit Screen Assembly 1 17 Firebox Top Assembly 1 18 J3980 Air Kit Door Assembly 1 19 Face Weldment 1 20 J4470 Air Deflector 1 21 Fireplace Top Insulation 1 22 J4052 Acces...

Page 18: ...Her White S36 1 4 Refractory Rear Her White S36 1 5 Refractory Btm Rear White S36 1 6 Refractory Btm Frnt White S36 1 1 2 4 3 6 5 Stacked Refractory Shown ACCESSORIES REFRACTORY STAIN KITS Use the re...

Page 19: ...ection Hi Temp Double Wall Pipe Snap Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double W...

Page 20: ...F0921 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SL...

Page 21: ...electing the proper venting system for your installation American National Standards Institute ANSI NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appli ances See Draft Section...

Page 22: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Page 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Page 24: ...7020 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...

Reviews: