background image

SuperiorFireplaces.us.com

127020-01_E

14

OPERATION AND MAINTENANCE GUIDELINES  

Continued

LOCATING ACCESS COVER PLATE

Sheet metal cover plates located underneath front hearth refractory may 

have shifted or moved out of place while fireplace was in transit. These 

cover plates must be kept in the proper location prior to using the fireplace 

(See Figure 23). 
For further operating guidelines, instructions and warranty infor-

mation, please refer to your homeowner's guide or contact your 

authorized dealer.

Figure 23 - Locating Access Cover Plate

Access Panel

REPLACEMENT PARTS

See Pages 16 to 18 for a complete replacement parts list. Use only 

parts supplied from the manufacturer.
Normally, all parts should be ordered through your IHP distributor 

or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1. The model number of the fireplace.

2. The serial number of the fireplace.

3. The part number.

4. The description of the part.

5. The quantity required.

6. The installation date of the fireplace.
If you encounter any problems or have any questions concerning the 

installation or application of this fireplace, please contact your dealer.

IHP

1508 Elm Hill Pike, Suite 108

Nashville, TN 37210

Visit us at SuperiorFireplaces.us.com

TECHNICAL SERVICE

You may have further questions about installation, operation, or 

troubleshooting. Please contact your IHP dealer for any questions 

or concerns. When contacting your dealer please have your model 

and serial numbers of your fireplace ready. You can also visit our web 

site at SuperiorFireplaces.us.com.

Summary of Contents for WRE3036WH

Page 1: ...ADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L au...

Page 2: ...Venting Installation 7 Optional Gas Line Installation 12 Operation and Maintenance Guidelines 13 Technical Service 14 Replacement Parts 14 Important Notices Canada 15 Parts 16 Accessories 18 Draft Sm...

Page 3: ...canposeasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESU...

Page 4: ...9 mm 29 737 mm 41 1042 mm 1 26 mm 1 26 mm 21 534 mm 8 204 mm 35 889 mm 37 940 mm 41 1042 mm 1 26 mm AIRSPACE TO COMBUSTIBLE MATERIAL 0 0 mm TO TOP SPACERS 0 0 mm TO BOTTOM 8 204 mm EACH SIDE NO COMBUS...

Page 5: ...air kit is available with this fireplace see Optional Outside Air Kit on page 7 MINIMUM CLEARANCE TO COMBUSTIBLES Ceiling 40 1016 mm minimum Back and sides of fireplace 3 4 19 mm minimum Floor 0 0 mm...

Page 6: ...concrete metal glass marble stone etc Provide a means to prevent the hearth extension from shifting and seal gap between the fireplace frame and hearth extension with a noncom bustible material see F...

Page 7: ...ability to individual site requirements Actual lengths gained after fitting overlaps must be taken into consideration lineal gain and are given in the lineal gain chart see Figure 6 Lineal gain is the...

Page 8: ...ht above offset rests on return elbow Straps must be securely nailed to rafters or joists see Figure 8 details A and B 3 Maximum length of pipe between supports return elbow or 12S 8DM is 6 of angle r...

Page 9: ...lowasshowninFigure10 They also provide complete separation from one floor space to another or attic space as required by most codes When the double wall pipe passes through a framed opening into an at...

Page 10: ...ny shingles as needed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 13 DO NOT NAIL THROUGH FLASHING CONE Installing Flashing on a Metal Roof When in...

Page 11: ...of that is within a horizontal distance of 10 feet see Figure 17 FINISHING FIREPLACE Combustible materials such as wallboard sheet rock drywall ply wood etc may make direct contact with sides and top...

Page 12: ...d connections must be tested for leaks after the installation is completed After ensuring that the gas valve is on apply soap and water solution to all connections and joints Bubbles formingshowaleak...

Page 13: ...of the appliance imme diately if doors are damaged and contact a qualified installer for repair Only doors certified with the ap pliance shall be used WARNING Do not slam or strike doors Damage can r...

Page 14: ...through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the fireplace...

Page 15: ...all Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT...

Page 16: ...SuperiorFireplaces us com 127020 01_E 16 PARTS 9 24 16 31 25 16 4 30 32 19 12 23 20 28 17 8 1 5 21 2 18 11 14 3 13 22 10 6 29 7 33 34 26 27 15 MODEL CATALOG NO WRE3036WS F0449 WRE3036WH F0450...

Page 17: ...5 Damper Can Collar 1 16 J8012 Kit Screen Assembly 1 17 Firebox Top Assembly 1 18 J3980 Air Kit Door Assembly 1 19 Face Weldment 1 20 J4470 Air Deflector 1 21 Fireplace Top Insulation 1 22 J4052 Acces...

Page 18: ...Her White S36 1 4 Refractory Rear Her White S36 1 5 Refractory Btm Rear White S36 1 6 Refractory Btm Frnt White S36 1 1 2 4 3 6 5 Stacked Refractory Shown ACCESSORIES REFRACTORY STAIN KITS Use the re...

Page 19: ...ection Hi Temp Double Wall Pipe Snap Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double W...

Page 20: ...F0921 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SL...

Page 21: ...electing the proper venting system for your installation American National Standards Institute ANSI NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appli ances See Draft Section...

Page 22: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Page 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Page 24: ...7020 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...

Reviews: