P126872-01
Installation and Operation Instructions
Unvented (Vent-Free) Gas
Compact Classic Hearth Fireplaces
P/N 126872-01 REV. C 12/2019
VCM3026ZMN
VCM3026ZMP
Models
PFS
®
US
Report No. F09-123
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases.
This is an unvented gas-fi red heater. It uses air (oxygen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation
section on
Page 7
of this manual.
WARNING: If the information in this manual is not followed exactly, a fi re or explosion may result
causing property damage, personal injury or loss of life.
– Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other
appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fi re department.
– Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.