background image

SuperiorFireplaces.us.com

127119-01C

24

PARTS

MODELS VCI3032ZMN AND VCI3032ZMP

 

17 

O

F

F

 

 

P

IL

OT

  

 O

N

 

H

I

 

 

 

  

  

  

  

 
 
 
 
 
 

 

 

 

 

 

 

L

O

 

12 

26 

 3 

28 
 

14 

13 

25 

15 

16 

21 

11 

10 

19 

20 

19 

23 

24 

22 

18 

1B 

1A 

1C 

27 

NOTE: Items 27 and 
28 are for natural 
gas only

CAT NO.

MODEL

F1790

VCI3032ZMN

F2055

VCI3032ZMP

 

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifi -

cally approved with this heater may result in property damage or personal injury.

Summary of Contents for VCI3032ZMN

Page 1: ...ir must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious inju...

Page 2: ...e replaced prior to operating fireplace insert system Safety 2 Local Codes 4 Commonwealth of Massachusetts Requirements 4 Unpacking 4 Product Identification 5 Remote Control Accessories 5 Product Feat...

Page 3: ...shut off gas supply do not try to light any appliance do not touch any electrical switch do not use any phone in your building immediately call your gas supplier from a neighbor s phone Follow the ga...

Page 4: ...to logs log base assembly and fireplace insert 4 Remove fireplace insert hood from carton insert 5 Check all items for any shipping damage If damaged promptly inform dealer where you purchased your fi...

Page 5: ...g It requires no outside venting There is no heat loss out a vent or up a chimney Heat is generated by both realistic flames and glowing embers When used without the blower the fireplace insert requir...

Page 6: ...om Outdoors Page 7 If your home does not meet all of the three criteria above proceed to Determining Fresh Air Flow for Heater Location Confined and Unconfined Space The National Fuel Gas Code ANSI Z2...

Page 7: ...pplicablelocalcodes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must provide...

Page 8: ...he fireplace insert is level If fireplace insert is not level log set will not work properly CHECK GAS TYPE Use the correct gas type natural or propane LP for your unit If your gas supply is not corre...

Page 9: ...Firmly tighten all screws installed during as sembly CAUTION Do not overtighten Metal can bend warp or break under excessive strain 5 Install trim after final finishing and or painting of wall INSTALL...

Page 10: ...ing and adjoining wall Carefully follow instructions below This will ensure safe installation Minimum Clearances For Side Combustible Material Side Wall and Ceiling A Clearancesfromsideoffireplacecabi...

Page 11: ...w black iron or steel pipe Internally tinned copper tubing may be used in cer tain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to fireplace insert If pi...

Page 12: ...9 Page 13 Apply a noncorrosive leak detection fluid to all joints Bubbles forming show a leak 4 Correct all leaks at once INSTALLATION Continued CONNECTING FIREPLACE INSERT TO GAS SUPPLY Installation...

Page 13: ...re 20 for masonry fireplace open ing 2 Install and properly ground GA3555 three prong 120 volt electrical outlet in fireplace insert Follow instructions included in kit see Accessories Page 28 3 Insta...

Page 14: ...s attached to the heater base assembly These markings contain important warranty and safety information WARNING Failure to position the parts in accor dancewiththesediagramsorfailuretouseonlyparts spe...

Page 15: ...HAND HELD REMOTE CONTROL ACCESSORIES RCKIT4001 AND TRC Installing Remote Receiver Unit 1 Disconnect switch wires from control valve 2 Remove screws attaching switch plate 3 Remove switch plate see Fig...

Page 16: ...tically within one minute when the remote selector switch is in the ON position after the pilot is lit 4 Press in and turn control knob clockwise to the OFF position 5 Wait five 5 minutes to clear out...

Page 17: ...Figure 30 NOTE The burner may light if hand held remote was on when selector switch was last turned off You can now turn burner on and off with hand held remote control unit IMPORTANT Do not leave se...

Page 18: ...All round burner flame holes should be open with a small blue flame present Some burner flame holes may become blocked by debris or rust with no flame present If so turn off heater and let cool Remov...

Page 19: ...e about 2 from where pilot flame comes out of pilot assembly see Figure 36 With unit off lightly blow air through air inlet hole You may blow through a drinking straw if compressed air is not availabl...

Page 20: ...clogged ODS pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect igniter cable 2 Free igniter cable if pinched by any metal or tub...

Page 21: ...burner orifice 1 Clean burner see Cleaning and Mainte nance Page 18 or replace burner orifice 2 Replace damaged burner 3 Replace gas control 1 Check burner for dirt and debris If found clean burner se...

Page 22: ...r 2 Gas leak See Warning statement above 1 Improper log placement 2 Drafts or other air currents affecting flame pattern 3 Air holes at burner inlet blocked 4 Burner flame holes blocked REMEDY 1 Open...

Page 23: ...allation operation or troubleshooting Please contact your IHP dealer for any questions or concerns When contacting your dealer please have your model and serial numbers of your appliance ready You can...

Page 24: ...13 25 15 16 21 11 10 19 20 19 23 24 22 18 1B 1A 1C 27 4 NOTE Items 27 and 28 are for natural gas only CAT NO MODEL F1790 VCI3032ZMN F2055 VCI3032ZMP WARNING Failure to position the parts in accordance...

Page 25: ...M 1 J3607 INJECTOR 0670 1 70MM 1 8 J3763 BURNER DUAL 24 2 9 J1958 SCREW HWH AB 8 18 X 38 2 10 J3857 ASM CARRIAGE BURNER WELDED 1 11 J1961 SCREW HX SLT WSR 10 32X3 8 4 12 FIREBOX BOTTOM 1 13 J3795 WIRE...

Page 26: ...m 127119 01C 26 11 14 8 8 14 9 3 14 9 9 2 1 7 10 14 12 5 14 13 28 15 23 4 27 6 17 16 18 19 20 21 22 22 23 14 24 25 14 26 PARTS FIREPLACE INSERT MODELS VCI3032ZMN AND VCI3032ZMP CAT NO MODEL F1790 VCI3...

Page 27: ...HOOD FIREBOX 1 8 FIREBOX SUPPORT 2 9 J3629 SCREW HWH SHLDR AB 10 X 63 4 10 FIREBOX TOP 1 11 OUTER BASE 1 12 FIREBOX WRAPPER 1 13 J3721 COVER PAINTED 1 14 J1955 SCREW HWH AB 10 16 X 38 46 15 J3923 ASS...

Page 28: ...or thermostatically controlled mode You can turn the gas log heater on and off without ever leaving the comfort of your easy chair A wall mount docking station is included F TEMP SET ON ROOM OFF MODE...

Page 29: ...be selected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected Includes thermostat assembly 25 of wire and two mounting screws WALL MOUNT ON OF...

Page 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a re hazard c...

Page 32: ...liance uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loca...

Reviews: