SuperiorFireplaces.us.com
127119-01C
23
SPECIFICATIONS
VCI3032ZMP
• Rating: 22,000/33,000 Btu/Hr
• Gas Type: Propane/LP Gas
• Ignition: Piezo
• Pressure Manifold: 8.0" W.C.
• Inlet Gas Pressure (inches of water):
Max. - 14" W.C., Minimum* - 11" W.C.
* For input adjustment
VCI3032ZMN
• Rating: 22,000/33,000 Btu/Hr
• Gas Type: Natural Gas
• Ignition: Piezo
• Pressure Manifold: 3.5" W.C.
• Inlet Gas Pressure (inches of water):
Max. - 10.5" W.C., Minimum* - 5" W.C.
* For input adjustment
REPLACEMENT PARTS
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• appliance will not produce specifi ed heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local
propane/LP or natural gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, operation, or
troubleshooting. Please contact your IHP dealer for any questions
or concerns. When contacting your dealer please have your model
and serial numbers of your appliance ready. You can also visit our
web site at SuperiorFireplaces.us.com.
See
Pages 24-27
for a complete replacement parts list. Use only
parts supplied from the manufacturer.
Normally, all parts should be ordered through your IHP distributor
or dealer. Parts will be shipped at prevailing prices at time of order.
NEVER USE SUBSTITUTE MATERIALS. USE OF NON-APPROVED PARTS
CAN RESULT IN POOR PERFORMANCE AND SAFETY HAZARDS.
When ordering repair parts, always give the following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any questions concerning the
installation or application of this appliance, please contact your dealer.