Operation
900684-01 06/2018
Innovative Hearth Products
DRT3000 Series Direct-Vent Gas Fireplaces
54
Continuous Pilot Ignition Switch
Fireplaces with an electronic gas valve have a continuous pilot ignition (CPI) switch installed in the control
compartment.
This switch allows the pilot to be switched from intermittent mode to continuous mode:
• Intermittent Mode—The pilot is extinguished when the fireplace is OFF.
• Continuous Mode—The pilot stays ON when the fireplace is OFF.
In periods of extreme cold, condensation may form on the glass door when the fireplace is OFF and the pilot is in
intermittent mode. Also, with the pilot in intermittent mode, the fireplace may
cycle startup
(i.e., the pilot and burner ignite,
but the burner extinguishes and reignites several times until the flue reaches the temperature for proper drafting).
• To save energy—switch to intermittent mode.
• For a standing pilot that will help prevent glass door condensation and cycle startup—switch to continuous mode.
NOTE:
Continuous mode is indicated by a pilot that comes ON and remains lit when the fireplace is OFF.
Installing the Firebox Liners
1.
Remove the three (3) optional firebox liner panels from the packing materials if purchased.
2.
Carefully position the rear panel, upper edge first, in the firebox against the rear wall.
3.
While holding the rear panel, carefully position the left side panel in the firebox.
4.
Carefully position the right side panel in the firebox.
NOTE:
Do not force the panels. Excessive force may cause breakage. If the panels are correctly positioned, they will fit snugly in
place.