12
Packaging List
Insert Body Packaging List
1 Insert Body
1 Log Set
1 Bag of Embers
1 Power Cord
1 Fasteners: 6 slotted 1/4" truss screws
6 speed nuts
9 spring clips
3 plastic adhesive wire restraints
1 Installation and Operation Manual
Decorative Facade Kit - One Required
Contemporary Facade kit
Surround Kits - One Required
Traditional 1-pc. (41"W x 29"H)
Traditional 3-pc. (41"W x 29"H, 48"W x 29"H, 41"W x
33"H or 48"W x 33"H)
Surround Kit Contents
1 Top Surround
2 Side Surrounds
3 Black Extruded Trim Pieces
2 Elbowed Trim Fasteners
Firebox Liner Kits - One Required
Tan Brick
Architectural Stone
Red Brick
Zen Garden
PRE-INSTALLATION
RATINGS
DRI3030TEN-40 / DRI2530TEN-40
DRI3030TEN-33 / DRI2530TEN-33
NATURAL GAS
LP GAS
NATURAL GAS
LP GAS
Max/Min Input BTUh 0-2,000 Feet
(0-610 M)
u
40,000/28,000
37,500/26,000
33,000/24,000
33,000/24,000
Manifold Pressure (IN. WC)
3.5
10.0
3.5
10.0
Min. Inlet Pressure (IN. WC)
5.0
10.5
5.0
10.5
P4 Efficiency
v
67%
69%
66%
68%
Orifice (DMS) 0-2,000 Feet (0-610 M)
u
1/8”
#49
#36
#51
u
Unit factory equipped for 0-2000 FT/0-610 M, In Canada 0-4500 FT/0-1370 M
v
Tested to CSA P.4.1-09 “Testing Method for Measuring Annual Fireplace Efficiency.
Electrical Rating: 120 VAC, 60 HZ, Less Than 2 Amps
Features
Installation Options
Manufactured (Mobile) Home
Natural Gas Or Propane (LP)
Bedrooms
Remote Control
Electrical
The standard blower motor requires 120 Volts AC for operation. The
fireplace is not dependent on the blower to operate.
WARNING - Electrical
Grounding Instructions - This appliance is equipped with a three-prong
(grounding) plug for your protection against shock hazard and should
be plugged directly into a properly grounded three-prong receptacle.
Do not cut or remove the grounding prong from this plug.
Electronic Valve
This appliance is equipped with an electronic valve and electronic pilot
ignition system (which can be switched from Intermittent to standing
pilot mode - see
Page 23
)
. External electrical 120 Volt power is required
to operate the blower system of this appliance and recommended to oper-
ate the burner system. This appliance is equipped with a battery backup
system in case of a power outage (see
Battery Backup
on
Page 21
for
more information).
Fuel
THIS APPLIANCE IS EQUIPPED FOR NATURAL GAS.
This appliance is equipped with an orifice sized for operation with natural
gas.
For conversion to LP/propane gas, see instructions provided with the
appliance.
Orifices and instructions necessary for LP/propane conversion are pro-
vided in the gas conversion kit (see
Page 36
for ordering information).
This appliance comes from the factory equipped to burn natural gas at a
specified elevation. Only IHP conversion kits can be used to convert from
NG to LP or LP to NG. Contact your IHP dealer for details.
Based on CSA P.4.1-09