NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure A 

Figure B

AUTO

ON

ON

OFF

BLOWER

PILOT

FLAME HEIGHT

BURNER

Illustrations are for example only. Your accessories may be different.

Les illustrations sont par exemple uniquement. Vos accessoires peuvent être différents.

Las ilustraciones son sólo ejemplos. Tu accesorios pueden ser diferentes.

HOMEOWNER’S INSTRUCTIONS -

 

ATTACHING SAFETY IN OPERATION WARNINGS

SAFETY LABEL  

DIAGRAMS

DIAGRAMAS DE ETIQUETAS  

DE SEGURIDAD

DIAGRAMMES DES ÉTIQUETTES 

DE SÉCURITÉ

ATTACHING SAFETY IN OPERATION WARNINGS

Your appliance has been furnished with safety instruc-

tion labels that are to be affixed to the operation and 

control points of the appliance.  A safety instruction 

label should be affixed next to the burner control 

switch where the appliance is turned on and off 

(See 

Figure A

)

 and the remote control handheld transmitter 

(See 

Figure B

)

.  The warnings should already have 

been put in place when the appliance initial set-up 

was completed.  If they are not affixed at these spots, 

locate the multi-lingual adhesive labels provided with 

these instructions and proceed as follows:

1.  Locate the control switch on the control panel 

of your appliance (verify the switch operates the 

appliance by turning it on and off).  Clean the 

surface on the control panel thoroughly to remove 

any dust and oils. Affix the label next to the burner 

control switch that controls the appliance 

(

Figure 

A

)

.  Choose the language primarily spoken in the 

home. 

2.  Locate the remote control transmitter and clean 

it thoroughly to remove any dust and oils.  Affix 

the label to the surface of handheld transmitter 

(

Figure B

)

.  Choose the language primarily spoken 

in the home. 

3.  If you are unable to locate the labels, please 

contact IHP or your nearest IHP dealer to receive 

additional safety instruction labels free of charge.
Cat. No. H8024 Replacement Label Kit 

IHP

SuperiorFireplaces.us.com

Note: English is red text on clear label. French and 

Spanish are white text on black label.

COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD 

EN OPERACIÓN

Su artefacto incluye etiquetas de instrucciones de 

seguridad que deben colocarse en los puntos de 

operación y control del artefacto. Se debe colocar una 

etiqueta de instrucciones de seguridad adyacente al 

interruptor de control del quemador donde se enciende y 

se apaga el artefacto 

(ver la 

Figura A

)

 y en el transmisor 

de control remoto 

(

Figura B

)

. Las advertencias ya deben 

haberse colocado cuando se completó la instalación 

inicial del artefacto. Si no están colocadas en estos 

lugares, encuentre las etiquetas adhesivas multilingües 

proporcionadas con estas instrucciones y prosiga de 

la siguiente manera:

1.  Identifique el interruptor de control en el panel de 

control del artefacto (verifique que el interruptor 

opera el artefacto encendiéndolo y apagándolo). 

Limpie bien la superficie del panel de control para 

quitar el polvo y aceite. Pegue la etiqueta adyacente 

al interruptor de control del quemador que controla 

el artefacto 

(

Figura A

)

. Seleccione el idioma que más 

se habla en la casa. 

2. Identifique el transmisor de control remoto y  

límpielo bien para quitar el polvo y aceite. Pegue la 

etiqueta en la superficie del transmisor 

(

Figura B

)

Seleccione el idioma que más se habla en la casa. 

3.  Si no puede encontrar las etiquetas, sírvase llamar 

a Innovative Hearth Products o al distribuidor  

de Innovative Hearth Products más cercano para 

recibir etiquetas de instrucciones de seguridad 

adicionales gratuitas. 
Juego de etiquetas de repuesto - Nº de cat. H8024 

IHP

SuperiorFireplaces.us.com

Nota: La etiqueta en inglés es transparente con texto 

rojo. Las etiquetas en francés y español son negras 

con texto blanco.

APPOSITION DES MISES EN GARDE RELATIVES  

À LA SÉCURITÉ D’UTILISATION

Votre appareil a été livré avec des étiquettes de sécurité 

qui doivent être collées à côté des dispositifs de contrôle 

du brûleur. Une étiquette de sécurité devrait être collée sur 

la plaque du récepteur contrôlant l’allumage de l’appareil 

(voir 

Figure A

)

 et sur le boîtier de la télécommande 

(

Figure B

)

. Les mises en garde auraient dû être collées au 

moment de l’installation initiale de l’appareil. Si ce n’est 

pas le cas, prenez les étiquettes adhésives multilingues 

fournies avec ces instructions et procédez comme suit :

1.  Repérez le contrôleur sur le panneau de contrôle de 

votre appareil (vérifiez que l’interrupteur contrôle 

le fonctionnement de l’appareil en le faisant 

basculer de Marche à Arrêt, et vice-versa). Nettoyez 

soigneusement la surface sur le panneau de contrôle 

pour éliminer la poussière et les traces de graisse 

ou d’huile. Collez l’étiquette à côté du bouton de 

contrôle du brûleur qui contrôle l’appareil 

(

Figure 

A

)

. Choisissez la langue qui est principalement parlée 

dans la résidence du propriétaire. 

2.  Repérez la télécommande et nettoyez-la soigneuse-

ment pour éliminer la poussière et les traces de 

graisse ou d’huile.  Collez l’étiquette sur le boîtier de 

la télécommande 

(

Figure B

)

.  Choisissez la langue 

qui est principalement parlée dans la résidence du 

propriétaire. 

3.   Si vous ne parvenez pas à localiser les étiquettes, s’il 

vous plaît contactez IHP ou votre revendeur le plus 

proche pour recevoir IHP étiquettes d’instructions 

de sécurité supplémentaires gratuitement.
Étiquettes de remplacement, n° cat. H8024 

IHP

SuperiorFireplaces.us.com

Remarque : Le texte anglais est rouge sur un support 

transparent. Le texte français et espagnol est blanc 

sur un support noir.

Summary of Contents for DRI2530TEN

Page 1: ...tely call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by...

Page 2: ...O CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact ac...

Page 3: ...o Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros l quidos inflamable...

Page 4: ...t Leveling 14 Fan Control Module Switch RDV 33 40 TCC models only 15 Installation 15 21 Venting Installation 15 USING THIS MANUAL Please read and carefully follow all of the instructions found in this...

Page 5: ...avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cett...

Page 6: ...porcionadas con estas instrucciones y prosiga de la siguiente manera 1 Identifique el interruptor de control en el panel de control del artefacto verifique que el interruptor opera el artefacto encend...

Page 7: ...pareil Figure A Choisissezlalanguequiestprincipalementparl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour limi...

Page 8: ...se or anemia those under the influence of alcohol and those at high altitudes Turn off gas and electrical power to the appliance and allow it to cool before cleaning or servicing the appliance If the...

Page 9: ...ver use solid fuels such as wood paper cardboard coal or any flammable liquids etc in this appliance Plated surfaces must be cleaned with glass cleaner and a clean soft cloth before firing the first t...

Page 10: ...ural gas or propane Is NOT for use with solid fuels Is approved for sitting rooms and or bedrooms This appliance is suitable for installation into masonry or factory built fireplaces Fireplace Require...

Page 11: ...a nationally recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified to ANSI Z21 88 CSA...

Page 12: ...r Propane LP Bedrooms Remote Control Electrical The standard blower motor requires 120 Volts AC for operation The fireplaceisnotdependentontheblowertooperate WARNING Electrical Grounding Instructions...

Page 13: ...A 31 1 2 800mm Front Opening Width B 19 1 2 495mm Height C 18 457mm Rear Width D 16 406mm Fireplace Depth Top View Left Side View Right Side View Front View A B C D Figure 3 Minimum Fireplace Cavity...

Page 14: ...learances Please note that the DRI3030TEN 33 and DRI2530TEN 33 mantel clear ances are 4 less than the DRI3030TEN 40 and DRI2530TEN 40 mantel clearances as shown in Figure 4A DRI3030TEN 40 and DRI2530T...

Page 15: ...for installation and vent termination These appliances are approved for use with the following vent kits Amerivent Flex Liner 3 X 35 3AFL 35 Adaptor w Flashing 4DCAT33 Termination Cap 4DVC Selkirk Fle...

Page 16: ...e sealed around the vent pipes Use a non combustible seal off plate i e 22 gage sheet steel or unfaced fiberglass insulation 8 lb per square foot density minimum to seal around the vent pipes Whicheve...

Page 17: ...l 33 000 BTU Natural Gas Input To convert input from 40 000 BTU s to 33 000 BTU s Assuming the front door is already removed 1 Remove the log rack Use a 5 32 allen wrench by removing two screws on the...

Page 18: ...oundpanelsinfrontoftheholesonthesurroundbrackets Next insert two slotted 1 4 truss screws for each side surround panel and secure loosely 5 Fasten the top surround panel with the remaining two truss s...

Page 19: ...Figure 15 The panel has keyhole slots where it mounts to the base Loosen the two nuts securing the panel using 3 8 wrench Carefully move out the panel far enough to access the back Do not pull the pa...

Page 20: ...leak test solution retighten if necessary If the pressure is not sufficient make sure the gas supply line is large enough the supply regulator is properly adjusted and the total gas load for the resid...

Page 21: ...air will result in bigger flames and more color To adjust the air shutter insert a regular screwdriver into the slide adjustment and slide it side to side see Figures 19a and 19b CAUTION The air shut...

Page 22: ...ance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier TO TURN OFF GAS TO APPLIANCE 1 Turn the burner ON OFF switch in the control...

Page 23: ...IT Proflame Stepper Electronic Pilot Assembly Electronic Pilot Assembly Unit Mounted Controls Unit Mounted Controls Intermittent Standing Pilot Mode On Auto Pilot Mode Switch Thisappliancecanbeswitche...

Page 24: ...to indicate that it is ready to synchronize with the Remote transmitter Install 3 AAA type batteries in the Remote transmitter battery bay located on the base of the Remote With the batteries already...

Page 25: ...ned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position s...

Page 26: ...per main burner operation at both high and low flame OPERATION DRI3030TEN Model Only No Blue Flame Center Soot at Flame Tip Dark Orange Flame IMPROPERLY BURNING FLAME Soot above Flame Tip No Soot at F...

Page 27: ...E RECEIVER BLOWER SPEED CONTROL PILOT ON AUTO SWITCH AC DC ADAPTER POWER OUTLET BOX 6 WHT 5 BLUE WHT BLK WHT BLK BLK BLK 4 GRN GRN 8 GRN 3 GRAY 14 RED 9 GRN 2 RED 1 RED 3 BLK 2 BLK 1 RED PILOT ROOM AI...

Page 28: ...W 10 ORG 13 BLK 12 BRN 14 RED 4 PUR WHT BLK BLK WHT 4 GRN 8 GRN 2 BLK 3 BLK 1 RED 9 WHT 3 GRAY 2 RED GRN 1 2 3 4 1 Figure 28C Electronic Control Schematic Model DRI3030TEN NOTE SWITCH CONDITIONS GIVEN...

Page 29: ...n those approved for use with this appliance o Check that the chimney and its outlet are open and free of soot block age or debris The venting system should be periodically examined by a qualified age...

Page 30: ...not attempt to substitute the materials used on these doors or replace cracked or broken glass Handle this glass with extreme care Glass is susceptible to damage Do not scratch or handle roughly while...

Page 31: ...Unplug the power supply cord from the electrical outlet prior to removing theblower Theblowercanbeaccessedthroughthebackwallofthefirebox Remove the insert face glass door log set and firebox liner pan...

Page 32: ...and lifting up slightly and then out away from the unit 3 Lay the facade face down on a soft surface that will not scratch the paint 4 Using a 3 8 socket remove the six nuts holding the left 1 and rig...

Page 33: ...ion on Pages 17 and 18 The main Burner comes on but then goes out Gas is not reaching the appliance Loose wires to the valve or ignition module Pilot flame is not engulf ing the sensor Obstructed vent...

Page 34: ...equires H8457 Conversion Kit For Model DRI2530TEN with Manual Hi Lo Regulator 26 H8507 Cassette Assembly NG 40 000 BTU if LP also requires H8459 Conversion Kit For Model DRI3030TEN with Auto Hi Lo Reg...

Page 35: ...DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS DRI3030TEN AND DRI2530TEN 1 27 26 2 3 4 5 15 6 7 16 37 14 36 25 33 34 21 22 23 13 32 31 30 29 28 8 17 9 10 11 20 19 33 21 34 22 23 12 24 18 38...

Page 36: ...0 BTU input to optional 33 000 BTU input Cat No Description H5924 Orifice Main Burner 36 Natural Gas 33 000 BTU H5925 Orifice Main Burner 51 Propane 33 000 BTU Firebox Panel Kits required accessory Ca...

Page 37: ...8 Black Trim Includes black trim x x x H8556 RDV DBV FP3341 D 33 x 41 Black Trim Includes black trim x x x H8557 RDV DBV FP3348 D 33 x 48 Black Trim Includes black trim x x x 75362 RDV DBV FP2941 B1 2...

Page 38: ...000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635 THIS APPLIANCE MUST BE PROPER...

Page 39: ...CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635 THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A...

Page 40: ...iance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any e...

Page 41: ...or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damage...

Page 42: ...distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial num...