105
Table 14.0-1:
Diagnostic codes and causes
Loca-
tion
Description
No.
Cause
2401 Reference
measurement
on
the dark reference element
13
No removal value can be
calculated for reference
measurement. Dust in device
because connector housing or
dummy connector not screwed on
2402 Reference
measurement
on
the light reference element
10
No distance value can be
calculated for reference
measurement.
Glare from another source of light
(905nm) or deviation in motor
rotation speed
2701
Processing of messages for
system diagnostics
1
Invalid diagnostic command
received. Software and firmware
incompatible
2702
Processing of requests for
diagnostics data
3
Invalid diagnostic value requested.
Software and firmware incompatible
2800
Processing of inputs for
detection zone changeover
2
2 detection zones active longer
than 1s
2800
Processing of inputs for
detection zone changeover
3
The detection zone changeover
that occurred does not correspond
to the requirement programmed in
the scanner.
2800
Processing of inputs for
detection zone changeover
4
More than 2 detection zones
selected during operation
2800
Processing of inputs for
detection zone changeover
6 Unevaluatable
data
or
defective
data quality for activation of
detection zone
2800
Processing of inputs during
scanner operation
8
No detection zone activated during
scanner operation
2801
Test of inputs for detection
zone changeover
1
Error during testing of inputs for
detection zone changeover,
internal fault
2802
Initialization of detection zone
changeover
3
The detection zone deactivation
that occurred does not correspond
to the requirement programmed in
the scanner.
2802
Initialization of detection zone
changeover
4
More than 2 detection zones
selected during power-ON
2802
Initialization of detection zone
changeover
6 Unevaluatable
data
or
defective
data quality for deactivation of
detection zone
2802
Initialization of inputs during
power-ON
8
No detection zone activated during
scanner starting
3016 Monitoring
the
access
authorization with one-time
password
11
Confirmed one-time password was
entered incorrectly
Summary of Contents for SD3-A1
Page 1: ......
Page 12: ...12...
Page 40: ...40 Fig 5 4 5 Considering the maximum measurement distance when safeguarding an area...
Page 60: ...60 Fig 6 2 1 Example of a zone pair changeover for an AGV on a curved route...
Page 61: ...61 Fig 6 2 2 Example of zone pair changeover with combined with reducing speed of the AGV...
Page 101: ...101 13 13 Dimensional drawings of the SD3 A1...
Page 102: ...102 13 14 Dimensional drawings of the mounting system...
Page 106: ......