background image

Version  20150101

Version  20150101

• 

Please refer to local regulations to determine the system wires size, type and 

temperature.
• 

Suntech modules are supplied with connectors used for system electrical 

connections. The recommended connectors are H&S Radox

TM

 connectors, Amphenol 

H4, Multi Contact MC4. Suntech strongly recommends using the genuine connector 
type specified by Suntech's product data sheet. Any choice of a different connector 
type other than specified may void the warranty of the module. 
• 

To ensure reliable electric connection and to prevent possible intrusion of 

humidity, H&S Radox

TM

 integrated twist locking connectors have to be fully mated 

together and then manually twisted clockwise ( a turn of around 90  shall be performed 
until the gap between the 2 connectors is closed), while two Amphenol H4 or two Multi 
Contact MC4 connectors must be mated and locked together until a click can be heard. 
• 

Long-term exposure to wet environments may cause connectors' poor connectivity, 

resulting in current leakage and poor conductivity which voids the warranty. Suntech 
recommends proper connector/cable/wire management to prevent moisture intrusion. 
Depending on the amount of humidity, Suntech recommends periodic inspections of 
the installation system to maintain optimal module performance. 
• 

The DC current generated by photovoltaic systems can be converted into AC 

and fed into a public Grid. As local utilities’ policies on connecting renewable energy 
systems to the Grids vary from region to region. Always seek the advice from a qualified 
system designer or integrator. Building permits, inspections and approvals by the local 
utility are generally required.
• 

Especially for larger installations Suntech recommends lightning protection 

following the local requirements and regulations.
• 

When the installation is finished and after connection to the grid please do a 

professional hand over to the owner including an installation protocol is required. 
Provide a clear documentation of the system to the owner consisting of following 
minimum data such as: user guide, system layout, data sheets, performance 
expectations, electrical system data e.g. a copy of the installation test report following 
minimum requirements of  IEC 62446 / IEC 60364-6.

 Grounding 

• 

For grounding and bonding requirements, please refer to regional and national 

safety and electricity standards. If grounding is required, use a recommended 
connector type for the grounding wire.
• 

For grounding, this guide refers to module frame grounding. If grounding is 

required, make sure module frames (metal exposed to touch) are always grounded.
• 

Suntech recommends always refer to local state and national code requirements 

for PV module grounding. Suntech highly recommends negative grounding if it's 
allowed by local authorities. 

o

No.13

No.14

No.13

No.13

Module

Grounding lug

M5 Bolt

Star washer

Module Frame

Flat washer

Split washer

M5  nut

Grounding holes

Insert exposed

copper wire

• 

Notice that WEEB teeth is positioned completely under the edge of the module 

frame.
• 

When position of solar module is finalized, torque fasteners to 20.5 N-m/15 ft-lb 

using general purpose anti-seize on threads.
• 

For more information, please contact supplier: BURNDY, http://www.we-llc.com

   2)  Use Schletter clamps to bond solar module to module mounting  brackets 
(grounding part is tested to UL467).

 

 

  tooth 

 

• 

Recommend fastening torque is 20.5N-m/15 ft-lb.

• 

For more information, please contact supplier: Schletter, http://www.solar.schletter.

de
   3)  Use ILSCO grounding lug to bond solar modules to module mounting brackets 
(grounding part is tested to UL467, UL File E34440/E6207).

No.11

 

 

No.11

No.12

 

teeth 

• 

When attaching the frame grounding hardware and wire to the frame it must 

be placed corresponding to the ground symbol stamped location to ensure proper 
electrical connection.
• 

Suntech recommends one of the following parts for grounding:

   1)  Use WEEB-DPF to bond solar modules to module mounting brackets (grounding 
part is tested to UL467)

No.12

Summary of Contents for STP185S-16/Tem

Page 1: ......

Page 2: ... General installation Installation method Attachment guidelines 11 Electrical Installation General installation Grounding 14 Maintenance No 1 Global Installation Guide for Suntech Power Photovoltaic Module Version 20150101 Please read carefully This document is binding for any warranty case Any installed PV system less than 500m from coastline please refer to the Near coast installation manual ...

Page 3: ...d to as module Wuxi Suntech Power Co Ltd referred to as Suntech Installers must read and understand this guide prior to installation For any questions please contact Suntech s Global Quality Customer Support department or our local representatives for more detailed information Installers must follow all safety precautions as described in this guide as well as local requirement and regulations by l...

Page 4: ...ling mechanical and electrical components Completely cover the module with an opaque material during installation to prevent electricity from being generated Do not wear metallic rings watchbands earrings nose rings lip rings or other metallic objects while installing or troubleshooting photovoltaic systems Follow the safety regulations eg safety rules for working on electrical power plant station...

Page 5: ... of 10 cm between the roof plane and the frame of the module is generally recommended Always observe the instructions and safety precautions included with the module support frames No 6 This installation manual is applicable for all pv system of 500 m or more away from the coastline If you need to install your system less than 500m from the coast line please refer to Near coast installation manual...

Page 6: ...es W series V series module No 9 2400 Pa Load 2400 Pa Wind Load 2400 Pa Snow Load 3800 Pa Load 3800 Pa Wind Load 3800 Pa Snow Load 5400 Pa Load 5400 Pa Snow Load 3800 Pa Wind Load Mounting system Clamping system Attachment to the long frame Length Use four clamps Use four clamps Use six clamps Clamping system Attachment to the short frame Use four clamps on short frame Use four clamps on the short...

Page 7: ... void the warranty It is not recommended to use modules with different configurations grounding wiring in the same system Excessive cables must be organized or fixed in an adequate way e g attached to the mounting structure by using non metallic cable ties Solar cables connectors and juction boxes should not be exposed to water exposure and snow and rain or water submersion for a long period of ti...

Page 8: ...al hand over to the owner including an installation protocol is required Provide a clear documentation of the system to the owner consisting of following minimum data such as user guide system layout data sheets performance expectations electrical system data e g a copy of the installation test report following minimum requirements of IEC 62446 IEC 60364 6 Grounding For grounding and bonding requi...

Page 9: ...ix months to verify that they are clean secure undamaged and free of corrosion Or else the warranty may be voided In the event of a ground fault condition NEVER wash or spray modules with water until ground fault has been identified corrected by an authorized solar inverter service technician and the inverter is fully operational This can cause electrocution or a serious safety issue If any proble...

Page 10: ... 1000 600 20 STP265 20 Wem 31 0 8 56 37 8 9 02 265 1000 600 20 STP260 20 Wem 30 9 8 42 37 7 8 89 260 1000 600 20 STP255 20 Wem 30 8 8 28 37 6 8 76 255 1000 600 20 STP250 20 Wem 30 7 8 15 37 4 8 63 250 1000 600 20 STP275S 20 Wem 31 1 8 85 38 5 9 34 275 1000 600 20 STP270S 20 Wem 30 8 8 77 38 3 9 28 270 1000 600 20 STP265S 20 Wem 30 5 8 69 38 1 9 22 265 1000 600 20 STP260S 20 Wem 30 2 8 61 37 9 9 17...