background image

Version  20150101

Version  20150101

No.5

2.  Barcode: each individual module has a unique serial number. The serial number has 
18 digits. The 15th and the 16th digits are the week code, and the 17th and the 18th 
digits are the year code. For example, STP xxxxxxxxxxxxxx2414 means the module was 
assembled and tested in the 24th week of 2014. Each module has only one bar code. It 
is permanently attached to the interior of the module and is visible from the top front 
of the module. This bar code is inserted prior to laminating.

Typical serial number barcode label

Do not remove any labels. Removing a label will make the Suntech warranty void.

3.  Sorting label: four different marks are shown on this sticker. "QC Pass" assures that 
the module has passed the quality control examination. "HIPOT" means that it has 
passed the insulation test. Finally modules are sorted out according to their output 
current, referred as a corresponding symbol "Ix" attached, in which x takes the value 
1, 2 or 3(I3 marks physically the highest current). To get optimal performance out of a 
string of modules it is recommended to connect only modules of the same "Ix" class (for 
example only I2 modules) in one given string. The function of the "Barcode" please refer  
to the "Barcode" instruction mentioned above.

Sorting label

Purpose of this guide

Product identification

• 

Never open electrical connections or unplug connectors while the circuit is under 

load.
• 

Contact with electrically charged parts of the modules, such as terminals, can 

result in burns, sparks and lethal shock whether or not the module is connected.
• 

Do not touch the PV module unnecessarily during installation. The glass surface 

and the frame may be hot; there is a risk of burns and electric shock.
• 

Do not work in the rain, snow or in windy conditions. 

• 

Avoid exposing cables and connectors to direct sunlight and scratches or cuts in 

order to prevent insulation degradation.
• 

Use only insulated tools that are approved for working on electrical installations.

• 

Keep children well away from the system while transporting and installing 

mechanical and electrical components.
• 

Completely cover the module with an opaque material during installation to 

prevent electricity from being generated.
• 

Do not wear metallic rings, watchbands, earrings, nose rings, lip rings or other 

metallic objects while installing or troubleshooting photovoltaic systems.
• 

Follow the safety regulations(eg. safety rules for working on electrical power 

plant stations) of your regions and for all other system components, including wires 
and cables, connectors, charging regulators, inverters, storage batteries, rechargeable 
batteries, etc.
• 

Under normal conditions, a photovoltaic module is likely to experience conditions 

that produce more current and/or voltage than reported at standard test conditions. 
Accordingly, the values of Isc and Voc marked on this module should be multiplied by a 
factor of 1.25 when determining component voltage ratings, conductor current ratings, 
minimum factor of fuse sizes, and size of controls connected to the PV output. 
• 

Only use same connectors to connect modules to form a string, or connect to 

another device. Removing the connectors will void the warranty.

Fire Safety

• 

Consult your local authority for guidelines and requirements for building or 

structural fire safety.
• 

Roof constructions and installations may affect the fire safety of a building; 

improper installation may create hazards in the event of a fire.
• 

Use components such as ground fault circuit breakers and fuses as required by 

local authority.
• 

Do not use modules near equipment or in places where flammable gases may be 

generated.
• 

The modules have been rated Fire Class C, and are suitable for mounting on to a 

Class A roof. 

No.4

Each module has three labels providing the following information:
1.  Nameplate: describes the product type; rated power, rated current, rated voltage, 
open circuit voltage, short circuit current, all as measured under standard test 
conditions; weight, dimensions etc.; the maximum system voltage is 600 volts or 1000 
volts depending on the product family DC for UL standard and 1000 volts DC for IEC 
standard. Depending on the products some are UL/IEC listed to 1 000 volts while other 
UL products are 600 volts. Check your nameplate or contact your local representative 
for details.

Installation safety

Summary of Contents for STP185S-16/Tem

Page 1: ......

Page 2: ... General installation Installation method Attachment guidelines 11 Electrical Installation General installation Grounding 14 Maintenance No 1 Global Installation Guide for Suntech Power Photovoltaic Module Version 20150101 Please read carefully This document is binding for any warranty case Any installed PV system less than 500m from coastline please refer to the Near coast installation manual ...

Page 3: ...d to as module Wuxi Suntech Power Co Ltd referred to as Suntech Installers must read and understand this guide prior to installation For any questions please contact Suntech s Global Quality Customer Support department or our local representatives for more detailed information Installers must follow all safety precautions as described in this guide as well as local requirement and regulations by l...

Page 4: ...ling mechanical and electrical components Completely cover the module with an opaque material during installation to prevent electricity from being generated Do not wear metallic rings watchbands earrings nose rings lip rings or other metallic objects while installing or troubleshooting photovoltaic systems Follow the safety regulations eg safety rules for working on electrical power plant station...

Page 5: ... of 10 cm between the roof plane and the frame of the module is generally recommended Always observe the instructions and safety precautions included with the module support frames No 6 This installation manual is applicable for all pv system of 500 m or more away from the coastline If you need to install your system less than 500m from the coast line please refer to Near coast installation manual...

Page 6: ...es W series V series module No 9 2400 Pa Load 2400 Pa Wind Load 2400 Pa Snow Load 3800 Pa Load 3800 Pa Wind Load 3800 Pa Snow Load 5400 Pa Load 5400 Pa Snow Load 3800 Pa Wind Load Mounting system Clamping system Attachment to the long frame Length Use four clamps Use four clamps Use six clamps Clamping system Attachment to the short frame Use four clamps on short frame Use four clamps on the short...

Page 7: ... void the warranty It is not recommended to use modules with different configurations grounding wiring in the same system Excessive cables must be organized or fixed in an adequate way e g attached to the mounting structure by using non metallic cable ties Solar cables connectors and juction boxes should not be exposed to water exposure and snow and rain or water submersion for a long period of ti...

Page 8: ...al hand over to the owner including an installation protocol is required Provide a clear documentation of the system to the owner consisting of following minimum data such as user guide system layout data sheets performance expectations electrical system data e g a copy of the installation test report following minimum requirements of IEC 62446 IEC 60364 6 Grounding For grounding and bonding requi...

Page 9: ...ix months to verify that they are clean secure undamaged and free of corrosion Or else the warranty may be voided In the event of a ground fault condition NEVER wash or spray modules with water until ground fault has been identified corrected by an authorized solar inverter service technician and the inverter is fully operational This can cause electrocution or a serious safety issue If any proble...

Page 10: ... 1000 600 20 STP265 20 Wem 31 0 8 56 37 8 9 02 265 1000 600 20 STP260 20 Wem 30 9 8 42 37 7 8 89 260 1000 600 20 STP255 20 Wem 30 8 8 28 37 6 8 76 255 1000 600 20 STP250 20 Wem 30 7 8 15 37 4 8 63 250 1000 600 20 STP275S 20 Wem 31 1 8 85 38 5 9 34 275 1000 600 20 STP270S 20 Wem 30 8 8 77 38 3 9 28 270 1000 600 20 STP265S 20 Wem 30 5 8 69 38 1 9 22 265 1000 600 20 STP260S 20 Wem 30 2 8 61 37 9 9 17...

Reviews: