OUT1_TYPE
‘0’ ~ ‘5’
0 = GPIO
1 = immobilizer
2 = Immobilizer & Auto active
Auto active means immobilizer is activated
automatically
when the vehicle starts parking.
3 = Pulse
4 = LED Out for indicating call status. Refer 7-2-3.
5 = Buzzer
OUT1_ACTIVE
‘0’ or ‘1’
0 = Open when out1 is active
1 = GND when out1 is active
PULSE1_NO
String
Pulse number when out1 type set to pulse.
Range : 0 ~ 9999
If pulse no is 9999, pulsing runs permanently.
PULSE1_ON
String
100ms
Active time of pulse1
Range : 0 ~ 9999
It should be set with even number.
PULSE1_OFF
String
100ms
Inactive time of pulse1
Range : 0 ~ 9999
It should be set with even number.
BAUD
‘0’ ~ ‘4’
It’s available when extra events support RS232.
Baud-rate
0 = No use
1 = 4800bps
2 = 9600bps
3 = 19200bps
4 = 38400bps
5 = 115200bps
If the device does not support RS232, it should be 0.