ST3500 User Manual
14
GROUP_SEND
‘0’ or ‘1’
Group Send for stored data
0 : Disable
1 : Enable. One packet can include up to 5 reports.
Group send is explained below.
MP_CHK
‘0’ or ‘1’
Main Power Disconnection Check
Disable (0) / Enable (1)
ANT_CHK
‘0’ or ‘1’
GPS Antenna Connection Error Check
Disable (0) / Enable (1)
BAT_CHK
‘0’ or ‘1’
Backup Battery Error Check
Disable (0) / Enable (1)
M_SENSOR
‘0’ ~’4’
Motion Sensor
Motion
Collision
Shock
0
Disable
Disable
Disable
1
Enable
Disable
Disable
2
Disable
Disable
Enable
3
Enable
Disable
Enable
4
Disable
Enable
Disable
5
Enable
Enable
Disable
6
Disable
Enable
Enable
7
Enable
Enable
Enable
CALL
‘0’ or ‘1’
Support Call with headset
Disable (0) / Enable (1)
GEO_FENCE
‘0’ or ‘1’
Support Geo-fence
Disable (0) / Enable (1)
DAT_LOG
‘0’ or ‘1’
Log out with RS232
0 = No Use
1 = Enable getting saved log data by RS232
<example>
[command] ST3500SVC;850000;02;1;120;0;0;0;0;1;1;1;0;0;0;0;0;0;0;0;0
[response] ST3500SVC;Res;850000;010;1;120;0;0;0;0;1;1;1;0;0;0;0;0;0;0;0;0
<notes>
** Function of M_SEMSOR can be used with the model that has motion sensor.
If shock or collision detection is enabled, device will report to server when gets any shock or collision.
** If this parameter has been customized, This table should be disregarded and you should follow
customized
operation document.