ST3500 User Manual
18
VER
“02”
Protocol Version
CHR_STOP_THRES_12
String
Voltage value to stop backup battery charging in 12V
vehicle.
DECIDE_BAT_12
String
Voltage value to check whether the vehicle’s battery is
12V.
OPERATION_STOP_THRES_12
String
Voltage value to protect vehicle battery.
The device operation stops if car battery voltage is lower
than this value in vehicle that has 12V power.
IGNDET_H
String
In case of virtual ignition, the vehicle can recognize
driving state when vehicle power is more than
IGNDET_H.
Default = ‘0’
IGNDET_L
String
In case of virtual ignition, the vehicle can recognize
parking state when vehicle power is less than IGNDET_L.
Default = ‘0’
<example>
[command] ST3500MBV;850000;02;10.5;22;19;8.00;18.00;0;0
[response] ST3500MBV;Res;850000;122;10.5;22;19;8.00;18.00;0;0
<note>
IGNDET_H and IGNDET_L are ‘0’, device check parking and driving automatically.
4-8. Set Parameters of Motion Sensor
HDR
DEV_ID
VER
CHR_STOP_THRES_12
DECIDE_BAT_12
OPERATION_STOP_THRES_12
IGNDET_H
IGNDET_L
VI_ON_THRES
VI_ON_DELAY
VI_ON_PERCENT
VI_OFF_THRES
VI_OFF_DELAY
VI_OFF_PERCENT
● Definition
: Set motion sensor parameters
Field
Definitions
Unit
Remark
HDR
“ST3500MSR”
Command type
DEV_ID
6 char.
Device ID
VER
“02”
Protocol Version
SHOCK_DELAY
String
Sec.
Delay for entering shock detection mode after ignition off
0 – Disable
Range : 1 ~ 21600 (5hour)