HEATING IN OUTDOOR OPERATION  
The TRANSFORM unit is outside the room to be heated. Outdoor operation is ideal for the transition period 
in which outside temperatures do no fall below 7°C.  

(If the outside temperature should however fall below 7°C 

continuously, we recommend indoor operation). 

Connect the air hose and the air outlet grid to the TRANSFORM 

unit as displayed in the illustration, the air hose connection piece and air outlet grid need to be exchanged. 
 
 
 
 
 
 
 
 
 
 
 
 
Set the function to „Heating“. The settable temperature range is between 15°C and 25°C target 
temperature. You can set this using the temperature control. 
 
The air with high oxygen content heated by the TRANSFORM unit is fed into the room via the air hose. This 
can be executed e.g. via a tilted window, a door or wall aperture. Make sure that no cold outside air can 
enter the room. For effective heating, we recommend our selection of various accessories which reduce or 
prevent entry of cold air into the room. 
 
Using the “Comfort Control- S Kit“ you can also control the TRANSFORM unit from inside using the remote 
control. 

 

Note: After switching on, or over, the ventilator operates, but the compressor only starts after the control lamp has flashed for  3 

minutes. Cooling effect may require a further 10 minutes. Further information is available under the part „Troubleshooting“.  

 

 

DEHUMIDIFICATION 

 

Humidity is extracted from the air, collected in the water tank and discharged via the condensation water 
outlet. Only air the room if the humidity of the outside air is below than in the inside room. Set the function 
to  “Dehumidity”. 
 
 
 

 

 

 
The rubber plug of the condensation water outlet is removed and a drainage hose attached. To collect the 
condensation water easily in a tank, a drainage hose is included in the scope of delivery which you can 
connect to the upper condensation water outlet. Allow water to flow out continuously in order to achieve 
higher dehumification capacity. In the dehumidify mode, you must not feed the room air outside with the 
extract air hose.  
 
 
 

 

 

 

 

 

Caution: In the dehumidify mode, separate setting of the ventilator is not provided, since the 

lowest ventilation level is already preset to ensure efficient dehumidification of ambient air. 

Summary of Contents for Klimatronic Transform 10500

Page 1: ...Instruction Manual ...

Page 2: ...60L day 70L day NOISE 50dB A 51 dB A 52dB A 53dB A 54dB A AIR CIRCULATION m h 360 400 420 450 450 COOLING AGENT R410a R410a R410a R410a R410a REMOTE CONTROL INCLUSIVE INCLUSIVE INCLUSIVE INCLUSIVE INCLUSIVE TIME SWITCH 0 24 STD 0 24 STD 0 24 STD 0 24 STD 0 24 STD DIMENSIONS mm WXDXH 300x480x630 300x480x630 300x505x778 300x505x778 300x505x778 NET WEIGHT 24 kg 25 kg 28 kg 29 5 kg 30 5 kg All figures...

Page 3: ...n damage the power cable 7 Since the TRANSFORM unit emits hot air please observe a sufficient minimum safety distance to each wall Fig 1 8 Despite the splash water protection you should not operate the TRANSFORM unit in moist areas such as e g swimming baths or similar areas 9 The colour of the TRANSFORM unit can change slightly due to direct solar radiation 10 The TRANSFORM unit is equipped with ...

Page 4: ...SFORM unit on a horizontal surface to ensure no water leaks out 4 The TRANSFORM unit must not be operated in an area with explosive and caustic substances 5 Clean the air filter regularly A contaminated air filter reduces capacity 6 Please wait at least 5 minutes after switching off the TRANSFORM unit before switching it back on to ensure the compressor is not damaged 7 The TRANSFORM unit is desig...

Page 5: ...om temperature by 1 C respectively up to a minimum temperature of 15 C 5 LED DISPLAY The display shows the required target temperature in operation By pressing the TEMP or TEMP switch the current ambient temperature is briefly displayed When pressing the TIMER switch the number of hours is briefly shown until activation or deactivation In the dehumification function dH or HP upside down is shown i...

Page 6: ...which the TRANSFORM unit is to switch off b After the flashing of the number of hours on the LED has stopped you can select the required function cooling heating dehumification and the required temperature c When the set number of hours has expired the TRANSFORM unit switches on automatically If you press the POWER switch before the time has expired the Timer programming is deleted and the TRANSFO...

Page 7: ... entry of warm air into the room Set the function to COOLING Set the target temperature using the temperature control The settable temperature range is between 17 C and 30 C target temperature The TRANSFORM unit must only be used in an ambient temperature of maximum 32 C Note After switching on or over the ventilator operates but the compressor only starts after the control lamp has flashed for 3 ...

Page 8: ... a room temperature of more than 23 C or less than 7 C The TRANSFORM unit can also be operated with heating function if the outside temperature is lower than 7 C However you must then ensure that the TRANSFORM unit is operated inside and the room temperature is at least 7 C HEATING IN INDOOR OPERATION The TRANSFORM unit is in the room to be heated Connect the air hose and the air outlet grid to th...

Page 9: ...it you can also control the TRANSFORM unit from inside using the remote control Note After switching on or over the ventilator operates but the compressor only starts after the control lamp has flashed for 3 minutes Cooling effect may require a further 10 minutes Further information is available under the part Troubleshooting DEHUMIDIFICATION Humidity is extracted from the air collected in the wat...

Page 10: ...en switching on the TRANSFORM unit I sense a smell What should I do Production related cause or incorrect storage of unit at e g dusty areas Odour development can arise on first use and after a longer period of non use by storing in unsuitable areas e g dusty areas Run the unit for a day The smell will disappear after a while In the case of intensive odour development air the room Can I operate th...

Page 11: ... cooling agent lines too high or too low Temporary error on measuring output temperature Please switch the TRANSFORM unit off and start it again after approx 30 minutes If the error occurs continuously the TRANSFORM unit requires specialist inspection E3 Incorrect signal This error message in the cooling function refers to too high ambient temperatures and in the heating function to too low ambien...

Page 12: ...nection elements for the air hose TF Comfort S Control Kit 4250058312037 Sensor controlled adapter for a wall or window boring with air lamellas integrated operating panel and a LCD remote control for convenient and automatic control of the TRANSFORM in outdoor operation TF Air Transfer Kit 4250058312044 Extension of the TRANSFORM with a second air hose The system can then e g air condition the li...

Page 13: ... NOTE CONCERNING PROTECTION OF ENVIRONMENT This product must not be disposed of via normal household waste after its service life but must be taken to a collection station for the recycling of electrical and electronic devices The symbol on the product the operating instructions or the packaging indicate such disposal procedures The materials are recycable in accordance with their respective symbo...

Reviews: