background image

 

 

INTRODUCTION / TECHNICAL DATA 
 

Congratulations on purchasing your SUNTEC WELLNESS KLIMATRONIC

®

 TRANSFORM unit. 

Your air-conditioner has been developed and manufactured in accordance with standards of state of the art 
technology. 
 
Please read the operating instructions carefully before connecting your TRANSFORM unit to the power 
supply in order to prevent damage from improper use. Pay special attention to the safety instructions. If you 
pass this TRANSFORM unit on to a third party, you must also include these operating instructions. Please 
keep these operating instructions in a safe place for any questions which may arise in future. 

Thank you for showing confidence in our product. We hope you enjoy a pleasant room climate with your 
Suntec air-conditioner.

 

 

MODEL 

TRANSFORM 

7000 

TRANSFORM 

9000 

TRANSFORM 

10500 

TRANSFORM 

12000 

TRANSFORM 

14000 

VOLT 

230V 50Hz AC 

230V 50Hz AC 

230V 50Hz AC 

230V 50Hz AC 

230V 50Hz AC 

POWER CONSUMPTION (W)  

760 W 

990 W 

1150 W 

1340 W 

 1530 W 

(Wb24 /Db35)

 

  

  

  

  

  

POWER CONSUMPTION (W) 

  

  

  

  

  

COOLING 

900 W 

1100 W 

1280 W 

1480 W 

1700 W 

HEATING 

(EN60335)

 

700 W 

950 W 

1100 W 

1300 W 

1500 W 

COOLING CAPACITY 

2.000 W  

2.600 W  

 3.000 W 

 3.500 W 

 4.000 W 

HEATING CAPACITY 

2.000 W 

2.600 W 

3.000 W 

3.500 W 

4.000 W 

(Wb24 / Db35)

 

  

  

  

  

  

DEHUMIDIFICATION 
CAPACITY 

(30, RH80%)

                      

30L/day 

50L/day 

50L/day 

60L/day 

70L/day 

NOISE 

50dB(A) 

51 dB(A) 

52dB(A) 

53dB(A) 

 54dB(A) 

AIR CIRCULATION [m³/h] 

360 

400 

420 

450 

450 

COOLING AGENT 

R410a 

R410a 

R410a 

R410a 

R410a 

REMOTE CONTROL 

INCLUSIVE 

INCLUSIVE 

INCLUSIVE 

INCLUSIVE 

INCLUSIVE 

TIME SWITCH 

0-24 STD 

0-24 STD 

0-24 STD 

0-24 STD 

0-24 STD 

DIMENSIONS (mm) WXDXH 

300x480x630 

300x480x630 

300x505x778 

300x505x778 

300x505x778 

NET WEIGHT 

24 kg 

25 kg 

28 kg 

29.5 kg 

30,5 kg 

 
All figures are approx. data. Characteristics pursuant to current Norm EN 14511. Subject to alterations.  
 

EASY TO OPERATE AND EASY TO MOVE AROUND 

  The TRANSFORM unit can be moved easily on rollers from room to room.  

  The air quantity can be adjusted via up to three ventilation levels.  

  The air flow can be very strong and reach up to 5 or 6 metres.  

  Installation by a specialist is not required  

  Simply plug into a normal household socket with an operating voltage of 230V/ 50Hz.  

  The extract air hose can be stored in the TRANSFORM unit for transport and when not in use.  

  This Suntec TRANSFORM unit operates in accordance with the heat pump principle. On account of the 

special, innovative construction of the TRANSFORM unit, its heating function is extremely efficient 
compared to conventional heating units.  
 

SCOPE OF DELIVERY 
 
1 x TRANSFORM unit 
1 x remote control 
1 x air hose 150 cm 
1 x air hose connector 
 

1 x bracket air hose 
1 x sir outlet grid 
1 x coarse filter top, 1 coarse filter 
bottom 
1 x activated carbon filter top 
 

1 x operating instructions 
1 x drainage hose 50 cm 
2 x sealing plug 
 

 
 
 

Summary of Contents for Klimatronic Transform 10500

Page 1: ...Instruction Manual ...

Page 2: ...60L day 70L day NOISE 50dB A 51 dB A 52dB A 53dB A 54dB A AIR CIRCULATION m h 360 400 420 450 450 COOLING AGENT R410a R410a R410a R410a R410a REMOTE CONTROL INCLUSIVE INCLUSIVE INCLUSIVE INCLUSIVE INCLUSIVE TIME SWITCH 0 24 STD 0 24 STD 0 24 STD 0 24 STD 0 24 STD DIMENSIONS mm WXDXH 300x480x630 300x480x630 300x505x778 300x505x778 300x505x778 NET WEIGHT 24 kg 25 kg 28 kg 29 5 kg 30 5 kg All figures...

Page 3: ...n damage the power cable 7 Since the TRANSFORM unit emits hot air please observe a sufficient minimum safety distance to each wall Fig 1 8 Despite the splash water protection you should not operate the TRANSFORM unit in moist areas such as e g swimming baths or similar areas 9 The colour of the TRANSFORM unit can change slightly due to direct solar radiation 10 The TRANSFORM unit is equipped with ...

Page 4: ...SFORM unit on a horizontal surface to ensure no water leaks out 4 The TRANSFORM unit must not be operated in an area with explosive and caustic substances 5 Clean the air filter regularly A contaminated air filter reduces capacity 6 Please wait at least 5 minutes after switching off the TRANSFORM unit before switching it back on to ensure the compressor is not damaged 7 The TRANSFORM unit is desig...

Page 5: ...om temperature by 1 C respectively up to a minimum temperature of 15 C 5 LED DISPLAY The display shows the required target temperature in operation By pressing the TEMP or TEMP switch the current ambient temperature is briefly displayed When pressing the TIMER switch the number of hours is briefly shown until activation or deactivation In the dehumification function dH or HP upside down is shown i...

Page 6: ...which the TRANSFORM unit is to switch off b After the flashing of the number of hours on the LED has stopped you can select the required function cooling heating dehumification and the required temperature c When the set number of hours has expired the TRANSFORM unit switches on automatically If you press the POWER switch before the time has expired the Timer programming is deleted and the TRANSFO...

Page 7: ... entry of warm air into the room Set the function to COOLING Set the target temperature using the temperature control The settable temperature range is between 17 C and 30 C target temperature The TRANSFORM unit must only be used in an ambient temperature of maximum 32 C Note After switching on or over the ventilator operates but the compressor only starts after the control lamp has flashed for 3 ...

Page 8: ... a room temperature of more than 23 C or less than 7 C The TRANSFORM unit can also be operated with heating function if the outside temperature is lower than 7 C However you must then ensure that the TRANSFORM unit is operated inside and the room temperature is at least 7 C HEATING IN INDOOR OPERATION The TRANSFORM unit is in the room to be heated Connect the air hose and the air outlet grid to th...

Page 9: ...it you can also control the TRANSFORM unit from inside using the remote control Note After switching on or over the ventilator operates but the compressor only starts after the control lamp has flashed for 3 minutes Cooling effect may require a further 10 minutes Further information is available under the part Troubleshooting DEHUMIDIFICATION Humidity is extracted from the air collected in the wat...

Page 10: ...en switching on the TRANSFORM unit I sense a smell What should I do Production related cause or incorrect storage of unit at e g dusty areas Odour development can arise on first use and after a longer period of non use by storing in unsuitable areas e g dusty areas Run the unit for a day The smell will disappear after a while In the case of intensive odour development air the room Can I operate th...

Page 11: ... cooling agent lines too high or too low Temporary error on measuring output temperature Please switch the TRANSFORM unit off and start it again after approx 30 minutes If the error occurs continuously the TRANSFORM unit requires specialist inspection E3 Incorrect signal This error message in the cooling function refers to too high ambient temperatures and in the heating function to too low ambien...

Page 12: ...nection elements for the air hose TF Comfort S Control Kit 4250058312037 Sensor controlled adapter for a wall or window boring with air lamellas integrated operating panel and a LCD remote control for convenient and automatic control of the TRANSFORM in outdoor operation TF Air Transfer Kit 4250058312044 Extension of the TRANSFORM with a second air hose The system can then e g air condition the li...

Page 13: ... NOTE CONCERNING PROTECTION OF ENVIRONMENT This product must not be disposed of via normal household waste after its service life but must be taken to a collection station for the recycling of electrical and electronic devices The symbol on the product the operating instructions or the packaging indicate such disposal procedures The materials are recycable in accordance with their respective symbo...

Reviews: