11 

 

 

TRANSFORM unit 
deactivates. 

 

On reaching the set required temperature, the 
TRANSFORM unit switches off automatically. Check 
manual setting of the required temperature as well as the 
TIMER setting. 

How is the m² or 
m³ data of the 
manufacturer 
calculated  

 

The m² or m³ data of the manufacturer for the various 
TRANSFORM units are average values related to a 
room height of 2.5 metres. It must be considered that 
such data can be clearly underscored or exceeded 
under certain circumstances. Circumstances which work 
against efficiency of the TRANSFORM units include e.g. 
bad insulation of the building, large window areas, south 
facing, attic apartment, many additional heat sources, 
such as e.g. number of persons, EDP, light, kitchen 
units, washing units etc.  

TRANSFORM unit 
does not cool 
correctly 

 

You achieve the most effective and economical cooling 
comfort if you already cool the room to be cooled when 
the room temperature is not yet heated up. Air 
conditioners operate more effectively if the temperature 
is to be maintained. To drastically cool the air and 
inventory in a fully heated room requires much more time 
and energy.  

E1 

Room temperature 
outside the function 
range: 
 
Room temperature 
inside the function 
range:
 

Observe all data in these operating instructions 
concerning function range.  
 
Temporary error of start temperature. Please switch the 
TRANSFORM unit off and start it again after approx. 30 
minutes. If the error occurs continuously, the 
TRANSFORM unit requires specialist inspection. 

E2 

Temperature of the 
cooling agent lines too 
high or too low 

Temporary error on measuring output temperature. 
Please switch the TRANSFORM unit off and start it 
again after approx. 30 minutes. If the error occurs 
continuously, the TRANSFORM unit requires specialist 
inspection. 

E3 

Incorrect signal 

This error message in the cooling function refers to too 
high ambient temperatures and in the heating function to 
too low ambient temperatures. Please observe the 
instructions relating to ideal operation of the 
TRANSFORM unit. This may also be a temporary error 
measurement between the start and output temperature. 
Please switch the TRANSFORM unit off and start it 
again after approx. 30 minutes. If the error occurs 
continuously, the TRANSFORM unit requires specialist 
inspection. 

E4 

Water tank full 

If the water tank is full, the warning sign "E4" appears in 
the display. To restart operation of the TRANSFORM 
unit, please remove the plug of the condensation water 
outlet to allow water to leak out. Please use an 
appropriate collection tank. When the water has been 
completely removed, please start the TRANSPORT unit 
again. The TRANSFORM unit can now be used as 
usual. 

DF 

De-icing mode 

This procedure is completely normal and protects the 
system from icing and failure. The unit starts 
automatically after approx. 15 minutes again (depending 
on the function setting). This procedure repeats itself 
regularly. 

 
 

SPARE PARTS AND ACCESSORIES SUPPLY (FAST CONVENIENT SUPPLY) 

 
You can obtain spare parts and accessories for your TRANSFORM unit from your local dealer. And  
at our website 

www.suntec-wellness.de

 

you will find further information on individual  

accessory products as well as information on obtaining our spare parts quickly and conveniently. 

Summary of Contents for Klimatronic Transform 10500

Page 1: ...Instruction Manual ...

Page 2: ...60L day 70L day NOISE 50dB A 51 dB A 52dB A 53dB A 54dB A AIR CIRCULATION m h 360 400 420 450 450 COOLING AGENT R410a R410a R410a R410a R410a REMOTE CONTROL INCLUSIVE INCLUSIVE INCLUSIVE INCLUSIVE INCLUSIVE TIME SWITCH 0 24 STD 0 24 STD 0 24 STD 0 24 STD 0 24 STD DIMENSIONS mm WXDXH 300x480x630 300x480x630 300x505x778 300x505x778 300x505x778 NET WEIGHT 24 kg 25 kg 28 kg 29 5 kg 30 5 kg All figures...

Page 3: ...n damage the power cable 7 Since the TRANSFORM unit emits hot air please observe a sufficient minimum safety distance to each wall Fig 1 8 Despite the splash water protection you should not operate the TRANSFORM unit in moist areas such as e g swimming baths or similar areas 9 The colour of the TRANSFORM unit can change slightly due to direct solar radiation 10 The TRANSFORM unit is equipped with ...

Page 4: ...SFORM unit on a horizontal surface to ensure no water leaks out 4 The TRANSFORM unit must not be operated in an area with explosive and caustic substances 5 Clean the air filter regularly A contaminated air filter reduces capacity 6 Please wait at least 5 minutes after switching off the TRANSFORM unit before switching it back on to ensure the compressor is not damaged 7 The TRANSFORM unit is desig...

Page 5: ...om temperature by 1 C respectively up to a minimum temperature of 15 C 5 LED DISPLAY The display shows the required target temperature in operation By pressing the TEMP or TEMP switch the current ambient temperature is briefly displayed When pressing the TIMER switch the number of hours is briefly shown until activation or deactivation In the dehumification function dH or HP upside down is shown i...

Page 6: ...which the TRANSFORM unit is to switch off b After the flashing of the number of hours on the LED has stopped you can select the required function cooling heating dehumification and the required temperature c When the set number of hours has expired the TRANSFORM unit switches on automatically If you press the POWER switch before the time has expired the Timer programming is deleted and the TRANSFO...

Page 7: ... entry of warm air into the room Set the function to COOLING Set the target temperature using the temperature control The settable temperature range is between 17 C and 30 C target temperature The TRANSFORM unit must only be used in an ambient temperature of maximum 32 C Note After switching on or over the ventilator operates but the compressor only starts after the control lamp has flashed for 3 ...

Page 8: ... a room temperature of more than 23 C or less than 7 C The TRANSFORM unit can also be operated with heating function if the outside temperature is lower than 7 C However you must then ensure that the TRANSFORM unit is operated inside and the room temperature is at least 7 C HEATING IN INDOOR OPERATION The TRANSFORM unit is in the room to be heated Connect the air hose and the air outlet grid to th...

Page 9: ...it you can also control the TRANSFORM unit from inside using the remote control Note After switching on or over the ventilator operates but the compressor only starts after the control lamp has flashed for 3 minutes Cooling effect may require a further 10 minutes Further information is available under the part Troubleshooting DEHUMIDIFICATION Humidity is extracted from the air collected in the wat...

Page 10: ...en switching on the TRANSFORM unit I sense a smell What should I do Production related cause or incorrect storage of unit at e g dusty areas Odour development can arise on first use and after a longer period of non use by storing in unsuitable areas e g dusty areas Run the unit for a day The smell will disappear after a while In the case of intensive odour development air the room Can I operate th...

Page 11: ... cooling agent lines too high or too low Temporary error on measuring output temperature Please switch the TRANSFORM unit off and start it again after approx 30 minutes If the error occurs continuously the TRANSFORM unit requires specialist inspection E3 Incorrect signal This error message in the cooling function refers to too high ambient temperatures and in the heating function to too low ambien...

Page 12: ...nection elements for the air hose TF Comfort S Control Kit 4250058312037 Sensor controlled adapter for a wall or window boring with air lamellas integrated operating panel and a LCD remote control for convenient and automatic control of the TRANSFORM in outdoor operation TF Air Transfer Kit 4250058312044 Extension of the TRANSFORM with a second air hose The system can then e g air condition the li...

Page 13: ... NOTE CONCERNING PROTECTION OF ENVIRONMENT This product must not be disposed of via normal household waste after its service life but must be taken to a collection station for the recycling of electrical and electronic devices The symbol on the product the operating instructions or the packaging indicate such disposal procedures The materials are recycable in accordance with their respective symbo...

Reviews: