11
TRANSFORM unit
deactivates.
On reaching the set required temperature, the
TRANSFORM unit switches off automatically. Check
manual setting of the required temperature as well as the
TIMER setting.
How is the m² or
m³ data of the
manufacturer
calculated
The m² or m³ data of the manufacturer for the various
TRANSFORM units are average values related to a
room height of 2.5 metres. It must be considered that
such data can be clearly underscored or exceeded
under certain circumstances. Circumstances which work
against efficiency of the TRANSFORM units include e.g.
bad insulation of the building, large window areas, south
facing, attic apartment, many additional heat sources,
such as e.g. number of persons, EDP, light, kitchen
units, washing units etc.
TRANSFORM unit
does not cool
correctly
You achieve the most effective and economical cooling
comfort if you already cool the room to be cooled when
the room temperature is not yet heated up. Air
conditioners operate more effectively if the temperature
is to be maintained. To drastically cool the air and
inventory in a fully heated room requires much more time
and energy.
E1
Room temperature
outside the function
range:
Room temperature
inside the function
range:
Observe all data in these operating instructions
concerning function range.
Temporary error of start temperature. Please switch the
TRANSFORM unit off and start it again after approx. 30
minutes. If the error occurs continuously, the
TRANSFORM unit requires specialist inspection.
E2
Temperature of the
cooling agent lines too
high or too low
Temporary error on measuring output temperature.
Please switch the TRANSFORM unit off and start it
again after approx. 30 minutes. If the error occurs
continuously, the TRANSFORM unit requires specialist
inspection.
E3
Incorrect signal
This error message in the cooling function refers to too
high ambient temperatures and in the heating function to
too low ambient temperatures. Please observe the
instructions relating to ideal operation of the
TRANSFORM unit. This may also be a temporary error
measurement between the start and output temperature.
Please switch the TRANSFORM unit off and start it
again after approx. 30 minutes. If the error occurs
continuously, the TRANSFORM unit requires specialist
inspection.
E4
Water tank full
If the water tank is full, the warning sign "E4" appears in
the display. To restart operation of the TRANSFORM
unit, please remove the plug of the condensation water
outlet to allow water to leak out. Please use an
appropriate collection tank. When the water has been
completely removed, please start the TRANSPORT unit
again. The TRANSFORM unit can now be used as
usual.
DF
De-icing mode
This procedure is completely normal and protects the
system from icing and failure. The unit starts
automatically after approx. 15 minutes again (depending
on the function setting). This procedure repeats itself
regularly.
SPARE PARTS AND ACCESSORIES SUPPLY (FAST CONVENIENT SUPPLY)
You can obtain spare parts and accessories for your TRANSFORM unit from your local dealer. And
at our website
www.suntec-wellness.de
you will find further information on individual
accessory products as well as information on obtaining our spare parts quickly and conveniently.