Diagram 2.
Pellet burner consignment elements
6. STORAGE OF PELLET BURNER
Pellet burners shall be stored in dry and
well ventillated spaces, free from any
gases, liquids, acids and oil vapours that
may damage the burner. Storing burner
and auger in spaces with fertilizers,
chlorinated lime, acids, chemicals, ect.
is not allowed. Recommended storage
temperature shall be from +5°С tо +40°С.
Recommended relative humidity -below
70%. When stored, the devices shall not
have direct contact with the ground,
placed on pallets, maximum two tiers and
in their original packaging. The storage
period is not more than 2 years from date
of manufacture. It is recommended that
every burner is tested before installation.
Quality and safety of the burner must
be confirmed by a test mentioned in the
warranty card.
7. MOUNTING OF THE BURNER
Mounting, installation and setup
of burner should be carried out
by authorized technician.
Installer shall advise the user
of the installation minimum
clearances
to
combustible
materials and liquids.
Recommended boiler chamber sizes for
mounting of Pell Mega pellet burner:
Diagram 3.
Mounting of Pell Mega pellet burner
to boiler combustion chamber
Pell 300
Mega
Pell 500
Mega
А
750
850
B
900
1000
C
750
800