TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
6
;
CAUTION! Hot surface!
Risk of burns if you touch the
running system. Burner housing,
body and flange are hot surfaces
during burner operation.
It is strictly prohibited to open
boiler inspection doors with the
burner running.
Also, exercise caution when
touching the observation port for
monitoring the burning process.
It may be hot.
1.2.3. Minimum
clearances
for
installation and combustibility of
construction materials
The applicable minimum clearances in
your country may differ from the ones
specified below. Please, consult your
installer.
The minimum distance from the burner,
heating boiler or exhaust gas pipe to
objects or walls must be at least 200 mm.
2. PRODUCT DESCRIPTION
The BURNiT Pell Mega pellet burner for
hot water boilers is designed to burn
only and exclusively wood pellets and it is
intended to heat up heating boilers. The
built-in control unit, automatic cleaning
function and internal pellet auger ensure
the automated operation of the burner
and optimal burning of the fuel.
2.1. Design.
The burner is made of high-quality
stainless steel able to withstand
temperatures of up to 1150°С. The
burner must be installed on a heating
boiler.
The burner consists of two parts:
combustion chamber tube and external
tube. On the upper part of the burner
there is a feeder chute to which the
pellet auger is attached.
The combustion chamber consists of
two tubes:
- Ember resistant steel tube
inside the
burner with holes for air intake along
its entire length, opening for the hot air
from the fuel ignition heater, opening for
photosensor.
- Outer stainless steel tube
. Between the
two tubes there is a gap which provides
for free circulation of the air necessary
both for cooling and oxygen supply into
the combustion chamber.
Diagram 1.
Pellet burner Pell Mega design
• Built-in controller.
The main control unit, located in the
burner, manages the entire heating
process. Controler functions:
Controler functions:
1) fully automated ignition and pellet
feed;
2) self-cleaning function, activation