4.10. Installing the CT Coil
The CT coil is one of the most important parts of the Sunsynk Max. This device reduces the power of the
inverter to prevent feeding power to the grid. This feature is also known as “Zero Export”.
Fit the coil (sensor) around the live cable on the main fuse feeding the building and run the cable back to
the inverter.
If using an external meter, you can extend the cable for more than 10 metres. Plese consult
the meter manual on distance.
Connect the other end of the CT coil into the inverter terminals marked as CT coil.
If the CT coil is fitted in the wrong
way then this variable will have neg-
ative instead of positive values when
the power is flowing into the house/
inverter. Also, the inverter export
limiting function will not work prop-
erly.