44--11
4
TROUBLESHOOTING
4.1.0
Error Messages and Corrective Measures
Error Message
No.
900
Chenille Main Shaft is not at the
Fix Position.
The main shaft does not stop at
35
°
.
Use the lever to set the main shaft
angle at 35
°
.
901
ID Check failure of chenille
board.
The control board ID setting was
wrong or communication
conditions are bad.
See “4.2 Control Board ID
Setting” to check the ID of each
control board.
910
Initialization failure ARM board.
Error has occurred in the middle
of initializing the ARM control
board.
Turn on or off the power. If
problems continue to occur, call
the nearest A/S service center.
911
Rotation failure of Needle motor.
The rotating motor of the needle
bar of the marked head develops
error while spinning.
Turn off the power and manually rotate the
needle bar to check any problems. After
checking is done, turn on the power again.
912
Origin failure of Needle motor.
The rotating motor of the needle
bar of the marked head did not
turn to the origin.
Turn off the power and rotate the needle bar
by hand to see if there is any problem. After
checking is done, turn on the power again.
913
Frame transfer failure by needle
height
This error could occur when the needle bar is
located below the frame, when the frame moves.
Perform manual trimming.
920
Initialization failure of BASE
board
This error could occur in the middle of
initializing the BASE control board.
Turn off and on the power.
921
Rotation failure of Looper motor
This error could occur, while the
looper rotating motor of the
marked head is in action.
Turn off the power and rotate the looper by
hand to see if there is any problem. After
checking is done, turn on the power again.
922
Origin failure of Looper motor
The looper rotating motor of the
marked head did not return to the
origin.
Turn off the power and rotate the looper by
hand to see if there is any problem. After
checking is done, turn on the power again.
923
Origin failure of trim mes
The trimming mes did not return
to the origin.
Turn off the power and open the needle plate to
see if there is any problem in the trimming mes.
924
Looper position error
The looper is located at the wrong
place.
Turn off the power and adjust the
looper’s position.
925
Chenille color change error
The color change was not
accurately handled.
Turn off the power and adjust the
looper’s position.
914
Failure of the needle bar height
adjusting
Time lapse error during needle bar
height adjustment
Potentia meter setting check for
needle bar height adjustment or
motor connection status check
990
Communication with sub board
failed
The communication between the
OP Box and the control board is
not proper.
Turn off the power and turn it on
again. Or check the dip switch of
the control board.
Description
Corrective Measure