33--77
⑦
Thread Break Sensor
Thread break can be regularly checked by setting the number of stitches for break check. When the pre-defined
number of stitches reaches, the machine checks whether thread break occurs.
- The default value is zero and it can be set in the range from 1 to 10 stitches by the unit of one stitch. If this
function is not going to be used, set the function at Disable (0).
⑧
Select Trim Mode
Chooses between the loop trimming mode and the chain trimming mode. The loop trimming mode performs
regular trimming, such as thread cutting. The chain trimming mode performs trimming and then threads the needle
and tightly fixes the thread.
- The default value is “Loop”. To shift to regular trimming, press “1” and then “confirm.”
⑨
Auto Frame Change
N/A
⑩
Taping Function
This function helps set up the taping device. When the taping device is installed, this function becomes abled. If it
is not installed, this function is disabled and unable to use.
- The default value is “NO”.
⑪
Auto Start After Backstitch
This function helps determine whether to activate automatic start after backstitch.
- The default value is “Yes”. If automatic starting is not desired, enter “0” to disable this function.
⑫
Start Point After Backstitch
This function helps set up the initial motion position of the entire needle bar from the stop position after backstitch
is conducted.
- The default value is 1[needle]. The value can be set at the range from 1 to 20[needle].