SXJS3018 DOUBLE-DECK SCISSOR LIFT 

 

The  lift  is  including  mechanical  system,  hydraulic  system,  pneumatic  system 

and electrical system as below:

Fig. 1

 

1. Pulling head   

2. Platform   

 

 

 

3. Machine arm 

4. Above protection lock 

5. Below protection lock   

6. Hydraulic cylinder 

7. Air cylinder 

8. Base  

 

 

 

 

9. Control box 

Chapter 2. Technical Parameters 

2.1 Main Technical Parameters

 

 

 

2.2 Dimensional Schematic Diagram

Fig. 2

 

Chapter 3. Installation and Adjustment 

3.1 Installation Environment 

The lifts should be installed in the indoor environment without dust and other 

pollution, and adequate lighting. Note the control cabinet should be placed in 

secure area. 

Model 

Lifting Height  Lifting Weight 

Hydraulic 

Pressure 

Pneumatic 

Pressure 

SXJS3018 

2000mm 

4000Kg 

25Mp 

0.4-0.6Mp 

Lifting Time 

Power 

Motor power 

Dimension(mm) 

90s 

380/220V,50Hz 

2.2Kw 

1560x1900x2000 

 

 

 

 

Fig. 2 Dimensions layout 

Summary of Contents for SXJS3018

Page 1: ...E DECK SCISSOR LIFT MANUAL Add No 21 Tongrun Road APEC Industrial Zone Zhifu District Yantai China Tel 0535 6853129 Fax 0535 6853815 http www ythaide com Please read this manual carefully before using...

Page 2: ...rs 4 5 Installation and Adjustment 5 6 Hydraulic System 8 7 Pneumatic system 9 8 Operation 9 9 Maintenance 11 10 Notes 12 11 Common Breakdowns and Solutions 13 12 Qualification Certificate 14 13 Inspe...

Page 3: ...water filter effectively When the lift works people and equipment should keep a certain distance no standing above and under the equipment and the car on lift can not take any staff The weight of the...

Page 4: ...oading bearing stress of sling used for handling should be more than 2 ton c Avoid damager or deformation for equipment during handling d Take suitable protective measurements in case of rain or snow...

Page 5: ...dvantages such as simple structure advanced technology easy operation and safety It is especially suitable for high precision wheel alignment and Auto s repair and maintenance The features as below 1...

Page 6: ...2 1 Main Technical Parameters 2 2 Dimensional Schematic Diagram Fig 2 Chapter 3 Installation and Adjustment 3 1 Installation Environment The lifts should be installed in the indoor environment without...

Page 7: ...n The lift with LOGO side toward the outside Refer to Fig 3 Hydraulic system connection diagram to pave the pipe but not connected in the ditch make certain protection to pipe connector 3 4 Infuse hyd...

Page 8: ...osition to change the motor rotation direction Connected to the gas source according to the pneumatic system connection diagram Fig 4 3 6 Pipe connection Power on click UP button to confirm the oil ou...

Page 9: ...fall in the same lock tooth Adjust the space around the lifts well Refer to Fig 2 Use a bolt to bore the bolt 14 holes in the ground Put in the bolts but not expanded Use a leveling tool to make sure...

Page 10: ...ction for too long time the gear pump could be damaged Fig 6 Hydraulic system diagram Chapter 5 Pneumatic System The connection of the pneumatic system refer to Fig 4 The schematic of the pneumatic sy...

Page 11: ...nd place the platform to the lowest location Then release the descending button 6 5 Drive a vehicle on the lifts Put rubber pads under the vehicle Make sure the lift points is directly to the rubber p...

Page 12: ...mes of using longest 2 years Release the used oil thoroughly Clean the oil tank and oil filter Fill in enough oil Check the oil level regularly Do not let anything dirt falls in the oil tank in case t...

Page 13: ...d Do not change the time setting of the time relay 8 7 The lock must be released before repairing or testing The protection lock must be released very well 8 8 If the power off suddenly when the facil...

Page 14: ...e button 2 The electromagne tic valve doesn t work 3 The control valve Is jammed 1 Check or change the button 2 Check the electromagnetic valve and the relative lines 3 Clean it 6 There is pressure in...

Page 15: ...is qualified according to the delivery inspection Dimension mm mm mm Product Number Corporate Representative Inspected by Date Yantai Haide Science And Technology Co Ltd Add No 21 Tongrun Road APEC I...

Page 16: ...ection items and results before sending out of factory are as follows No Inspection items unit Standard Value measured value 1 Lifting height mm 2000 2 Lifting capacity Kg 3000 3 System pressure Mp 25...

Page 17: ...n Lifting Platform SXJS3018 2 2 Rubber Pad 4 3 Electrical Control Box Assembly 1 4 Pneumatic FRL 1 5 Compound Pad 14 8 6 Expansion Bolt M16 120 8 7 Gasket 16 8 Plastic band 10 9 Inspection Report 1 10...

Page 18: ...16 SXJS3018 DOUBLE DECK SCISSOR LIFT Figure I Electric Schematic Diagram...

Page 19: ...17 SXJS3018 DOUBLE DECK SCISSOR LIFT Figure II Foundation Installation Diagram...