background image

- 24 -

10.5 Conduct regular maintenance according to the user manual instruction, to make sure the unit
running is in good condition.

●If there is a fire, disconnect the power immediately and put the fire out with fire extinguisher.

●The unit’s operating environment should be free of gasoline, ethyl alcohol and other flammable materials
to avoid explosions or fire.

●Malfunction: if any malfunction occurs, find the reason, fix it and then reboot he unit. Never reboot the
unit forcibly if the cause of the malfunction has not been eliminated. If there is refrigerant leakage or
frozen liquid leakage, switch the unit off. If it is not possible to turn the unit off from the controller then
disconnect the main power supply..

●Never short connect the wire for device protection otherwise, in case unit malfunction, the unit will not be
protected normally and could be damaged.

Summary of Contents for BYC-007TF1

Page 1: ...anual Full Inverter Swimming Pool Heat Pump Thank you very much for purchasing our product please keep and read this manual carefully before you install heat pump MODEL NO BYC 007TF1 BYC 010TF1 BYC 013TF1 BYC 017TF1 BYC 021TF1 ...

Page 2: ......

Page 3: ...ration Manual 1 2 Wire controller 1 3 Wire controller box and sponge pad to be installed on the heat pump shell 1 4 Drain pipe 2 m 1 5 Drain pipe connector 1 6 Rubber shock absorber 4 7 Heat Pump Unit The pipe connector has been installed on the machine 1 ...

Page 4: ...able for use in winter all water must be drained from the unit during winter or it could freeze inside the unit causing damage to the internal components Content Accessories 5 Safety 6 Heat pump working principle 7 Installation of the unit 8 Installation of the pipeline 10 Installation of optional accessories 13 Installation and operation of electric devices 14 Instruction for operation 17 Initial...

Page 5: ...ce vibration and noise 6 Heat pump unit 1 SET For heating water In order for the system to work the following parts are required No Name Qty use 1 Water pump 1 To circulate the pool water 2 Filter system 1 To clean the pool water which passes through the heat pumps 3 Water pipes system 1 To connect the equipment and circulate the water in the pool NOTE The types and quantity of the water pipes val...

Page 6: ...f you smell anything burning turn off the manual power switch immediately stop operation and contact the after sale service department Continued abnormal operation may cause electric shock fire When the unit needs to be removed or re installed please ensure that the work is carried out by qualified professionals If the installation is not correct it may cause unit operation failure electric shock ...

Page 7: ...increases the heat to form a very hot gas which then passes through the CONDENSER water heat exchanger It is here that the heat exchange occurs as the heat from the hot gas is transferred to the cool swimming pool water circulating through the heat exchanger The pool water becomes warmer and the hot gas returns to its liquid form as it flows through the CONDENSER coil The gas then passes through t...

Page 8: ...tal conditions 4 2 Installation check Check the model number name etc to avoid incorrect installation Make sure there is enough space for installation and maintenance Install in a dry well ventilated place and make sure there are no obstructions around the air inlet and outlet Make sure the supporting base is strong enough and prepared to that shocks can be avoided The power supply and diameter of...

Page 9: ...operation and maintenance Figure 2 Horizontal installation space requirements mm 4 4 Heat pump dimensions Figure 3 Heat pump dimensions A B C D E F G H I J K BYC 007TF1 BYC 010TF1 591 836 379 335 98 640 98 107 290 26 11 BYC 013TF1 BYC 017TF1 BYC 021TF1 641 896 389 363 128 640 128 107 340 26 11 ...

Page 10: ...ctive plates on the surface of the units when handling to avoid scratches and deformation Double check that the support base is strong enough before fixing the unit The heat pump will produce condensation water remember to provide a drainage channel when making the installation base Please install shock absorber on the surface of the base Figure 5 Lifting diagram 5 Installation of pipelines 5 1 At...

Page 11: ...the beam of the base see Figure 5 When connecting the water inlet and outlet pipes use two pipe wrenches to adjust the two parts of the pipes and make sure the water inlet and outlet pipes do not twist see Figure 6 Figure 6 5 2 Instructions 5 2 1 Symbols Figure 7 5 2 2 Pipeline installation diagram Controller Heat Pump Water temp sensor wire Swimming Pool Pump signal wire Pump Drainage Drainage Fe...

Page 12: ...raulic calculation should be made after selecting the pipe diameter If the resistance is more than the pump head then a more powerful pump or larger pipes are required 5 2 4 Required Water Quality Bad quality water will produce more limescale and sand this kind of water should be filtered and demineralized The water quality should be analyzed before operating the unit PH value conductivity Chlorid...

Page 13: ...e units are installed in parallel place more demand on the water pump requirement 6 2 Water pipe selection The selection of the water pipe should be based on the actual system specifications The flow switch can be installed horizontally or vertically If installed the direction of the water flow must be upwards and NOT downwards The flow switch must be installed on a straight pipeline and there mus...

Page 14: ... each other Do not install the units if the power supply specifications are not met After all wiring connections have been completed check them again carefully before switching on the power 7 2 Electrical Wiring Specification Model Electrical Wiring Specification BYC 007TF1 BYC 010TF1 BYC 013TF1 BYC 017TF1 3 2 5 mm BYC 021TF1 3 4 0 mm Terminal Terminal cable max 4 mm POWER SUPPLY Circulation Pump ...

Page 15: ... please refer to figure 12 To water pump AC 220 50Hz 60hz Maximum 250W Figure 11 Figure 12 7 4 Electric wiring diagram COMP COMPRESSOR GND GROUND AMBT AMBIENT TEMPERATURE SENSOR WFS WATER FLOW SWITCH LOW LOW PRESSURE SWITCH HIGH HIGH PRESSURE SWITCH COIL EVAPORATOR COIL TEMPERATURE SENSOR OWT INWT INLET OUTLET WATER TEMPERATURE SENSOR ...

Page 16: ... 16 Figure 13 Electrical wiring diagram ...

Page 17: ... 17 8 Instructions of operating 8 1 Wire controller Function of buttons 8 2 Definition of display ...

Page 18: ...When the display is locked the logo appears Please unlock the controller before the other operations every time Attention Before you start make sure the filtration pump is running and that water is flowing through the heat pump 8 4 Operation Mode Selected Hold the button for 3 seconds to change the below four operating modes each time Mode ECO Inverter Choose this heating mode that the heat pump o...

Page 19: ...hen press the to save the setting When setting the water temp the icon SET will light on the left one is Setting temp the right one is the Outlet water temp After finished the setting the icon SET will extinguish the left one will become Inlet water temp the right one Outlet water temp 8 6 Clock setting Press the button to enter the clock setting interface Clock display on right bottom flashes Cha...

Page 20: ...g and go back to the main interface Cancel the Timer Hold the button for 3 seconds to cancel all the timer setting 8 8 Definition of other icons Defrosting Compressor 4 way valve A Fan Speed Signal of Water pump Wi Fi function Attention With the indication of the functions or key parts it is helpful for service team to maintain or repair the heat pump 8 9 Manual defrosting Hold and for 3 seconds t...

Page 21: ...Hz C21 EEV open degree C23 Heat pump current A C24 Compressor current A C25 DC fan motor1 speed Rpm C26 Compressor target frequency Hz C27 DC fan motor2 speed Rpm C28 Control system software version C29 Driver software version C30 Controller software version 8 12 Parameter setting Hold and for 3 seconds to enter the Parameter setting press to select the parameter then press and to set the new data...

Page 22: ...heck that supply voltage can meet the requirement of rated voltage Check that air inlet and outlet are working correctly Check that the electrical leakage protector works correctly 9 3 Adjustment Process Check that switch of display controller works properly Check that function keys on display controller work properly Check that indicator lights work properly Check that drainage works properly Che...

Page 23: ...month If there is too much dirt we can use a paintbrush dipped in gasoline to clean the evaporator After restarting the unit following a long period of inactivity please do the following examine and clean the equipment carefully clean the water pipe system check the water pump and fasten all the wire connections Always use original replacement parts 10 2 Refrigerant Check the refrigerant filling c...

Page 24: ...ls to avoid explosions or fire Malfunction if any malfunction occurs find the reason fix it and then reboot he unit Never reboot the unit forcibly if the cause of the malfunction has not been eliminated If there is refrigerant leakage or frozen liquid leakage switch the unit off If it is not possible to turn the unit off from the controller then disconnect the main power supply Never short connect...

Page 25: ... 25 11 Fault analysis and solution method ...

Page 26: ...nput kW 1 07 1 45 1 9 2 53 3 09 Rated Current A 4 9 6 6 8 6 11 5 14 Compressor Mitsubishi Mitsubishi Mitsubishi Mitsubishi Mitsubishi Refrigerant R32 R32 R32 R32 R32 Heat Exchanger Titanium Titanium Titanium Titanium Titanium Air Flow Direction Horizontal Horizontal Horizontal Horizontal Horizontal Water Flow Volume m3 h 2 5 3 5 4 5 5 5 6 5 Kind of defrost by 4 way valve by 4 way valve by 4 way va...

Page 27: ... 27 13 After sale service If your heat pump does not operate normally please turn off the unit and cut off the power supply at once then contact our service center or technical department ...

Page 28: ......

Reviews: