- 21 -
Press
to enter the Running parameters checking, then press
and
to check the below
parameters as below:
N°
Description
Unit
C01
Ambient temperature
°C
C02
Evaporator coil temperature
°C
C03
Exhaust temperature
°C
C04
Return temperature
°C
C07
Titanium heat exchanger temperature
°C
C08
Water inlet temperature
°C
C09
Water outlet temperature
°C
C13
Temperature sensor failure
C14
Refrigerant system failure
C15
Inverter driver failure
C16
Device output
C17
Running status
C18
AC voltage
V
C19
DC voltage
V
C20
Actual frequency
Hz
C21
EEV open degree
C23
Heat pump current
A
C24
Compressor current
A
C25
DC fan motor1 speed
Rpm
C26
Compressor target frequency
Hz
C27
DC fan motor2 speed
Rpm
C28
Control system software version
C29
Driver software version
C30
Controller software version
8.12 Parameter setting
Hold
and
for 3 seconds to enter the Parameter setting, press
to select the parameter,
then press
and
to set the new data for the below parameters.
Code
Description
Default
Scope
P01
Inlet water temp. in Heating mode
27
°
C
8~40
°
C
P02
Inlet water temp. in Cooling mode
27
°
C
8~28
°
C
P03
Inlet water temp. in Auto mode
27
°
C
8~40
°
C
P04
Water temp. difference before restart
1
°
C
1~18
°
C
P05
Heat pump ON/OFF when reached the desired
water temp.
1
1 ON, 0 OFF