Serial Flash Programmer[S550-SFWv3] Operation Manual
108
8.3.6.
Data Switch Display
With the “Multi Data Mode”, you can select programming data on S550-SFWv3. Following shows how to select
the data.
*When there is no data downloaded to the internal memory, the display does not change to “
Data Switch Display Mode
”. Also, when the
S550-SFWv3 main unit is in energy saving mode, the display does not change to “
Data Switch Display Mode
”
①
Move to
“
Data Switch Display Mode
”
・
When center display is in the “
Error Information Display Mode
”, press the “FUNC” switch on
S550-SFWv3 once, and ”
S.
”,”
P.
” appear on the center display. Within 3 seconds after ”
S.
”,”
P.
” are
displayed on the center display, press the “START” switch on S550-SFWv3 once, then you can select data.
②
Switch data
・
Press the “FUNC” switch on S550-SFWv3 and “
P
”,”
1.
” Through “
P
”,”
4.
” appear, you can switch data.
* Selected data is displayed initially.
*When there is no operation for 3 seconds after “
P
”,”
1.
” through “
P
”,”
4.
” are displayed, the center display goes back to the
default screen.
③
Exit
“Data Switch Display Mode”
・
Press the “START” switch on S550-SFWv3 once to select the data and go back to the default screen.
If there is no operation for 3 seconds, the data is not selected and the screen goes back to the default screen.
* When a data is selected, buzzer sounds.