SUNIX Co., Ltd.
TEL : +886-2-8913-1987
Email : [email protected]
USSR Zone 9
IDLE - International
Date Line
NZST - New Zealand
Standard
NZT - New Zealand
+12 hours
Midnight
4.
SNTP Sever URL:
set the SNTP server IP address.
5.
Daylight Saving Period:
set up the Daylight Saving beginning time and Daylight Saving ending time. Both will be
different in every year.
6.
Daylight Saving Offset (mins):
set up the offset time.
7.
Switch Timer:
display the switch current time.
8.
Click
Apply
.
SNTP Configuration interface
4.1.17
IP
S
ECURITY
IP security function allows users to assign 10 specific IP addresses that have permission to access the switch through web
browser for switch management security.
IP Security Mode:
when this option is in
Enable
mode, the
Enable HTTP Server
and
Enable Telnet Server
check
boxes will then be available.
Enable HTTP Server:
when this check box is checked, the IP addresses among Security IP1 ~ IP10 will be allowed to
access via HTTP service.
Enable Telnet Server:
when checked, the IP addresses among Security IP1 ~ IP10 will be allowed to access via
telnet service.
Security IP 1 ~ 10:
Assign up to 10 specific IP address. Only these 10 IP address can access and manage the
switch through the Web browser
And then, click
Apply
button to apply the configuration
[NOTE]
Remember to execute the “Save Configuration” action, otherwise the new configuration will lose when switch
power off.