Low Fan Speed With Certain Blade Servers (6911651)
This issue was fixed in ILOM 3.0.6.11.
With Sun Blade X6275 (and possibly Sun Blade X6270) blades, the chassis fan speed
can run as low as 1800 RPM, even when the blades are powered on.
With CMM ILOM 3.0.3.11.c (SW 3.1.3), the CMM sets the fans to a minimum speed
of approximately 2000 RPM.
Issues Fixed in ILOM 3.0.6.11b
ILOM 3.0.3.32 Displays Incorrect Power Failures in Event
Log With Certain PSU Firmware (6865366)
This issue was fixed in ILOM 3.0.6.11b.
With ILOM 3.0.3.32 installed on the Sun Blade 6000 CMM, incorrect power
assert/deassert errors are displayed in the event log with A231 PSUs running
firmware 18.18 only.
Issues Fixed in ILOM 3.0.6.11
Chassis Amber LED Turns on When PSU0 Is Plugged
Into the Chassis (6866727)
This issue was fixed in ILOM 3.0.6.11.
Sometimes, the chassis amber LED lights when a power supply is plugged into the
PS0 slot.
CMM Web Interface Slow Response (6853788)
This issue was fixed in ILOM 3.0.6.11.
When the chassis contains blades that do not run ILOM, displaying blade
information through the CMM web interface can be slow.