Chapter 2
Hardware Notes and Issues
11
NEM LEDs (6713414)
shows the LED behavior for 10/100/1000 MB LEDs for Sun Blade 6048
network express modules (NEMs). The LED color can be different, depending on the
server module that is using the Ethernet port.
Note –
See the chassis and NEM documentation for specifics on the connectors
available for each NEM.
Power Supply Connections (6615994) (6576346)
The Sun Blade 6048 modular system contains two power supply modules that each
have a power rating of 8400 W. Each power supply has three power connectors, with
a 20A circuit per connector.
If you do not need the total power capacity of the power supplies, you have the
alternative to use only two of the power connectors on the power supply. If you use
only two power connectors, use the two to the right of each power supply (PS1-AC1,
PS1-AC0 and PS0-AC1, PS0-AC0).
If you do use the two power connectors for a power supply, you will see IPMI SEL
logs for missing AC connections in both CMM and server module SP log.
Additionally, if the SNMP trap is configured, there SNMP traps will be sent out. The
PSU Fault LED will be on. The DC-OK LED and the AC LED for the power supply
will be off.
Further information on operating the power supplies with two connectors is
available in S
un Blade 6048 Modular System Service Manual.
TABLE 2-1
LED States for Server Module and the NEMs
Sun Blade Server
Module
10 MbE (Right LED)
100 MbE Right LED)
1000 MbE (Right LED)
X6220
off
Amber
Green
X6250
off
Amber
Green
X6450
off
Amber
Green
T6300
off
Green
Amber
T6320
off
Green
Amber
T6340
off
Amber
Green
Summary of Contents for Sun Blade 6048
Page 1: ...Sun Blade 6048 Modular System Product Notes Part No E23072 01 April 2011...
Page 12: ...4 Sun Blade 6048 Modular System Product Notes April 2011...
Page 39: ...Chapter 3 ILOM Notes and Issues 31...
Page 40: ...32 Sun Blade 6048 Modular System Product Notes April 2011...
Page 42: ...34 Sun Blade 6048 Modular System Product Notes April 2011...